Daikin · Heat pump

Green Rx LED on solid Network: terminal 1 / 2 miswired

Medium severity Daikin FIT DH6VS/DH7VSA

What the control is telling you

Green receive LED stays on solid.

Applies to: DH6VS***1*A*, DH7VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Likely causes

  • Terminal 1 and 2 swapped at the indoor unit, thermostat or outdoor unit
  • Short between terminal 1 and 2
  • Terminal 1 or 2 shorted to C or R (24 VAC)

Test and repair steps

  1. Kill power at the disconnect before opening the control box or touching wiring.
  2. Check and correct the terminal 1 / terminal 2 communication wires at every unit.

Models that show this code

11 models in Daikin FIT DH6VS/DH7VSA

DH6VS*181DH6VS*241DH6VS*301DH6VS*361DH6VS*421DH6VS*481DH6VS*601DH7VSA2410DH7VSA3610DH7VSA4210DH7VSA4810

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Daikin 3P761829-1B FIT outdoor unit installation & service reference, Network Troubleshooting p.47 (printed page). Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.