E51 Communication problem seen by the outdoor board
What the control is telling you
Thermostat shows 51, outdoor board display shows E51. The outdoor control board sees a communication problem on the network.
Applies to: DH6VS***1*A*, DH7VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)
Likely causes
- Communication wiring unplugged or broken
Test and repair steps
- Kill power at the disconnect before opening the control box or touching wiring.
- Check the communication wires (terminals 1 and 2) between indoor, outdoor and thermostat.
- Then follow the network troubleshooting steps (DS1/DS7 dip switches, learn button).
Models that show this code
11 models in Daikin FIT DH6VS/DH7VSA
Other codes on the same units
- E44 Outdoor temperature out of operating range
- E47 System verification test blocked by indoor heat
- E49 Charging mode blocked by indoor heat
- E50 Voltage problem on the control board
- E56 Suction temperature sensor out of range
- E58 Compressor overload (OL) sensor open
- Eb0 Indoor airflow near zero
- Eb9 Indoor airflow below what is needed
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.45 (printed page). Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.