Daikin · Heat pump

E42 Low supply voltage

High severity Daikin FIT DH6VS/DH7VSA

What the control is telling you

Thermostat shows 42, outdoor board display shows E42. Supply voltage to the unit is low.

Applies to: DH6VS***1*A*, DH7VSA[24-48]10A* (FIT and Enhanced Capacity/High Efficiency FIT)

Likely causes

  • Low line voltage

Test and repair steps

  1. Check breakers and fuses.
  2. Make sure the unit is fed the voltage on the rating plate.
  3. If voltage is low at the disconnect, call the utility.

Models that show this code

11 models in Daikin FIT DH6VS/DH7VSA

DH6VS*181DH6VS*241DH6VS*301DH6VS*361DH6VS*421DH6VS*481DH6VS*601DH7VSA2410DH7VSA3610DH7VSA4210DH7VSA4810

Other codes on the same units

  • E38 Compressor voltage problem
  • E39 Control board may need replacing (thermistor input)
  • E40 Compressor setup does not match the unit
  • E41 Low refrigerant
  • E43 High supply voltage
  • E44 Outdoor temperature out of operating range
  • E47 System verification test blocked by indoor heat
  • E49 Charging mode blocked by indoor heat

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Daikin 3P761829-1B FIT outdoor unit DC6VS/DH6VS/DC9VSA/DH7VSA installation & service reference, Troubleshooting table p.44 (printed page). Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.