Kinghome heat pump error codes

55 codes with causes and test steps.

CodeMeaningSeverity
A1Outdoor fan IPM module protectionHigh
C4ODU jumper cap errorMedium
C5Jumper cap missing or wrongMedium
C8ODU drive jumper cap errorMedium
E1High pressure protection / high-pressure sensor faultHigh
E2Indoor coil anti-freeze protectionMedium
E3Low pressure protection / low-pressure sensor faultHigh
E4Compressor discharge temperature too highHigh
E5Overcurrent protectionMedium
E6Indoor/outdoor communication faultHigh
E8High temperature resistance (overload) protectionMedium
E9Water overflow protectionMedium
F0Refrigerant recovery modeLow
F1Indoor room temperature sensor faultMedium
F2Sensor fault (indoor coil or outdoor condenser)Medium
F3Outdoor ambient temperature sensor faultMedium
F4Sensor fault (outdoor condenser or discharge)Medium
F5Outdoor discharge temperature sensor faultMedium
F6Frequency limit for overload / ODU tube sensor faultMedium
F8Frequency reduced - overcurrentLow
F9Frequency reduced - high discharge temperatureLow
H3Compressor overload protectionHigh
H4Overload protection (high condensing pressure)High
H5IPM module protectionCritical
H6Fan motor feedback fault (indoor or outdoor)High
H7Compressor out-of-stepHigh
L3Outdoor DC fan motor faultHigh
L9Power limit protectionMedium
P0Compressor minimum-frequency test / driver resetLow
P1Compressor rated-frequency test displayLow
P2Compressor maximum-frequency test displayLow
P3Compressor intermediate-frequency test displayLow
P5Compressor phase overcurrentHigh
P6Main-to-driver communication errorHigh
P7Module temperature sensor circuit faultMedium
P8Power module over-temperatureHigh
U1Compressor phase current detection circuit faultHigh
U3DC bus voltage drop faultMedium
U5Whole-unit current detection faultHigh
U7Four-way valve abnormalHigh
ACOutdoor fan startup failureHigh
AEOutdoor fan current detection errorHigh
AJOutdoor fan out-of-stepHigh
EEMemory chip faultHigh
EUFrequency reduced - module too hotLow
FHFrequency reduced - anti-freezeLow
HCPFC protectionHigh
LCCompressor start failureHigh
LPIndoor and outdoor unit mismatchHigh
PAAC current protectionHigh
PHDC bus voltage highHigh
PLDC bus voltage lowHigh
PUCapacitor charging failureHigh
PcDrive current detection errorHigh
ULOutdoor fan overcurrentHigh

Models covered

KD24UHIKD24UHOKD30UHIKD30UHOKD36UHIKD36UHOKD42UHIKD42UHOKD48UHIKD48UHOKD60UHIKD60UHOKM09HEDIKM09HF1DIKM09HT1DIKM12HEDIKM12HF1DIKM12HT1DIKM18HEDIKM18HF1DIKM18HT1DIKM21HF1DIKM24HF1DIKM24HT1DIKU24UH2IKU36UH2IKU36UHOKU48UH2IKU60UH2IKU60UHO

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.