Kinghome · Heat pump

X-FAN icon X-FAN (fan dry-off) active

Normal status Kinghome KM HEDIKinghome KM HT1DI

What the display is showing

The X-FAN icon on the remote means the indoor fan will keep running after the unit is switched off so the coil dries out. It works only in COOL or DRY and starts switched off after power-up. The HEDI remote text gives about 10 minutes of fan run-on; the HT1DI control description gives 2 minutes at low speed.

Applies to: Kinghome KM09HEDI, KM12HEDI, KM18HEDI wall mini-splits; Kinghome KM09HT1DI, KM12HT1DI, KM18HT1DI, KM24HT1DI wall mini-splits

What to do

  1. Cool or Dry mode press the X-FAN button on the remote.
  2. Press it again to switch the function off.

Models that show this code

7 models in Kinghome KM HEDI, Kinghome KM HT1DI

KM09HEDIKM09HT1DIKM12HEDIKM12HT1DIKM18HEDIKM18HT1DIKM24HT1DI

Other codes on the same units

  • PH DC bus voltage high
  • PL DC bus voltage low
  • PU Capacitor charging failure
  • SE Energy-saving mode active
  • Temp display select Indoor display shows set, room or outdoor temperature
  • Timer lamp Timer lamp lit (timer set)
  • Turbo icon Turbo mode active
  • dd Pilot (test) run in progress

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Kinghome KM09-12-18HEDI service manual, sec. 6.1 item 16; sec. 6.2; Kinghome KM09-12-18-24HT1DI service manual, sec. 6.2 (13) X-fan mode. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.