Kinghome · Heat pump
H2 Defrosting mode 2 selected (remote display)
What the display is showing
H2 on the remote while the unit is off means defrosting mode 2 will be used once the unit is switched on. The indoor unit sends that choice to the outdoor unit with the next command. Not a fault.
Applies to: Kinghome KM09HEDI, KM12HEDI, KM18HEDI wall mini-splits
What to do
- With the unit off, press MODE and AUXILIARY together on the remote to switch between defrosting mode 1 and 2.
Models that show this code
3 models in Kinghome KM HEDI
Other codes on the same units
- 88 Sleep curve editing (remote)
- C5 Jumper cap missing or wrong
- E6 Indoor/outdoor communication fault
- F1 Indoor room temperature sensor fault
- F2 Sensor fault (indoor coil or outdoor condenser)
- H1 Defrosting mode 1 selected (remote display)
- H6 Fan motor feedback fault (indoor or outdoor)
- + - + - + - Forced defrost request (remote key sequence)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Kinghome KM09-12-18HEDI service manual, sec. 7.7 switchover function for defrosting mode. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.