Kinghome · Heat pump
H3 Compressor overload protection
What the control is telling you
The compressor overload input is open; on Ultranixx units the board saw it open for 3 s.
Applies to: Kinghome KM09HT1DI, KM12HT1DI, KM18HT1DI, KM24HT1DI wall mini-splits; Kinghome KM09HF1DI to KM24HF1DI wall mini-splits (Gree GFH..DA/DB); Kinghome Ultranixx Eco KD24UHO to KD60UHO outdoor units with KD..UHI air handlers
Likely causes
- Overload terminal loose or open
- Faulty outdoor board
Test and repair steps
- Check the overload terminal; it should be closed (under 1 ohm on the wall units).
- Refer to overload checks in the manual.
- Replace the board if needed.
Models that show this code
21 models in Kinghome KM HT1DI, Kinghome KM HF1DI, Kinghome Ultranixx Eco
Other codes on the same units
- F5 Outdoor discharge temperature sensor fault
- F6 Frequency limit for overload / ODU tube sensor fault
- F9 Frequency reduced - high discharge temperature
- H4 Overload protection (high condensing pressure)
- H5 IPM module protection
- H6 Fan motor feedback fault (indoor or outdoor)
- H7 Compressor out-of-step
- L3 Outdoor DC fan motor fault
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Kinghome KM09-12-18-24HT1DI service manual, sec. 9.1 error code list; Kinghome KM09-24HF1DI service manual, sec. 11.1 error code list; Kinghome Ultranixx Eco KD24-60UHO service manual, sec. 3.3-3.4. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.