Kinghome · Heat pump

E5 Overcurrent protection

Medium severity Kinghome KM HT1DIKinghome KM HF1DI

What the control is telling you

Running current went too high and the compressor and outdoor fan stopped (whole unit in heating).

Applies to: Kinghome KM09HT1DI, KM12HT1DI, KM18HT1DI, KM24HT1DI wall mini-splits; Kinghome KM09HF1DI to KM24HF1DI wall mini-splits (Gree GFH..DA/DB)

Likely causes

  • Unstable supply voltage
  • Low supply voltage with heavy load
  • Dirty evaporator

Test and repair steps

  1. Measure the supply voltage at the unit under load.
  2. Clean the evaporator and condenser.
  3. Check compressor and wiring connections.
  4. Retest after the supply is stable.

Models that show this code

9 models in Kinghome KM HT1DI, Kinghome KM HF1DI

KM09HF1DIKM09HT1DIKM12HF1DIKM12HT1DIKM18HF1DIKM18HT1DIKM21HF1DIKM24HF1DIKM24HT1DI

Other codes on the same units

  • C5 Jumper cap missing or wrong
  • E1 High pressure protection / high-pressure sensor fault
  • E2 Indoor coil anti-freeze protection
  • E3 Low pressure protection / low-pressure sensor fault
  • E6 Indoor/outdoor communication fault
  • E8 High temperature resistance (overload) protection
  • E9 Water overflow protection
  • F0 Refrigerant recovery mode

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Kinghome KM09-12-18-24HT1DI service manual, sec. 9.1 error code list; Kinghome KM09-24HF1DI service manual, sec. 11.1 error code list. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.