Kinghome · Heat pump
U7 Four-way valve abnormal
What the control is telling you
The reversing valve did not work correctly; heating stops.
Applies to: Kinghome KM09HT1DI, KM12HT1DI, KM18HT1DI, KM24HT1DI wall mini-splits; Kinghome KM09HF1DI to KM24HF1DI wall mini-splits (Gree GFH..DA/DB)
Likely causes
- Supply below 175 VAC
- 4V terminal loose or broken
- Failed reversing valve coil
Test and repair steps
- Check supply.
- Check the 4V terminal.
- Replace the coil.
Models that show this code
9 models in Kinghome KM HT1DI, Kinghome KM HF1DI
Other codes on the same units
- P7 Module temperature sensor circuit fault
- P8 Power module over-temperature
- U1 Compressor phase current detection circuit fault
- U3 DC bus voltage drop fault
- U5 Whole-unit current detection fault
- + - + - + - Forced defrost request (remote key sequence)
- Cool lamp Cool lamp lit (cooling mode)
- Dry lamp Dry lamp lit (dry mode)
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Kinghome KM09-12-18-24HT1DI service manual, sec. 9.1 error code list; Kinghome KM09-24HF1DI service manual, sec. 11.1 error code list. Summarized in our own words; check the original manual for your model.
Homeowner looking at this code? See what it means for you and when to call a technician.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.