Air conditioner troubleshooting guides
40 guides. Troubleshooting guides for air conditioner equipment. Each one lists the likely causes and what to check, in order.
Carrier (29)
- AUTO mode operation
The unit picks COOL, FAN or HEAT automatically based on the set temperature. Fan speed cannot be set in AUTO. - Charging a system with flammable refrigerant
Charging and leak-test steps for R454B / flammable refrigerant systems. - Checking room area against refrigerant charge
Room area limits for an A2L/R454B system serving a room or ducted rooms. - Clean the indoor unit air filter
Clean the filter at least every two weeks. A clogged filter lowers cooling efficiency and air quality. Do not use water inside the unit and do not dry - COOL mode operation
Cools, dries and filters the room air. - Decommissioning and refrigerant recovery
Safe recovery steps before decommissioning a flammable refrigerant system. - Downflow coil installation
Downflow installs need an adapter when the coil is rotated 90 degrees. - DRY mode operation
Dehumidifies, filters and slightly cools the room. It is not a replacement for a dehumidifier. - Dust comes out of indoor or outdoor unit
Dust can build up during long non-use and is released at power-on. Covering the unit during long idle periods reduces it. - Erratic operation or unit does not respond
Interference from cell phone towers or remote boosters can cause malfunction. - FAN only mode operation
Filters and circulates room air without changing room temperature. - Horizontal coil installation
The coil can be set on a work platform, roof truss, floor joist hangers or blocks. It allows airflow in either direction. - Indoor and outdoor units make noise
Normal sounds from refrigerant flow and thermal expansion. A low hiss during operation, at start, at stop, or during defrost is normal. - Indoor unit emits white mist
Normal in humid areas when the room air and conditioned air differ greatly in temperature. - Indoor unit makes noise
Some noises are normal. A rushing sound can occur when the louver resets. A squeak can occur in HEAT mode from plastic parts expanding or contracting. - Long periods of non-use
Steps before storing the unit for an extended time. - Outdoor fan does not run
Fan speed is controlled during operation to optimize performance, so it may stop or change speed as normal. - Outdoor unit makes noise
The unit produces different sounds depending on the current operating mode. - Pre-season check before frequent use
Checks before starting the unit after a long non-use period or before heavy use. - Refrigerant line connection and brazing
Connect the field tubing to the coil stubs. Evacuate and reclaim as needed, and leak check before insulating. - Secondary condensate protection above living space
If the unit sits in or above a living space, protect against overflow water damage. - Shut the unit off immediately if
Stop the unit and do not try to fix the problem yourself. Contact an authorized service provider. - T1 return plenum sensor installation
Mount the T1 sensor in the return plenum within reach of the supplied extension wire. - T2 pipe temperature sensor installation
Mount the T2 sensor on the coil using the clip for the matching model. - Unit changes from COOL or HEAT to FAN mode
This is normal. The unit may switch to FAN to prevent frost, or the set temperature was reached and the compressor is off. - Unit does not turn on when ON/OFF is pressed
A 3-minute protection delay prevents overloading. The unit cannot restart within three minutes of being turned off. - Unit emits a bad odor
The unit can absorb odors from the room such as furniture, cooking or smoke, and release them during operation. Moldy filters also cause odor. - Upflow coil installation
Set the cased coil on the furnace discharge opening and check that it is level. - Waste (sewer) line condensate connection
Prevent sewer gas from entering the unit through the drain line.
Navien (11)
- Check for air or nitrogen contamination in the system
Method to tell whether non-condensable gas is in the refrigerant circuit. - Compressor discharge temperature protection (T5)
If compressor discharge temperature T5 goes above its set maximum, the unit stops until T5 reaches the recovery temperature of 194 F (90 C). The unit - IPM module temperature too high
The IPM module is overheating. The fault code is not legible in the extracted pages. - Outdoor coil high-temperature protection (T3)
If T3 goes above the maximum set temperature of 147 F (64 C), the unit stops and waits until T3 falls to the recovery point. The unit restarts when T3 - PCB detects overcurrent
The PCB detected compressor or system current above the protection threshold. No code number is printed for this fault on these pages. - Replace accumulator
The accumulator is brazed into the suction and discharge lines. Recover refrigerant before cutting. - Replace compressor
The compressor is replaced by recovering refrigerant, cutting the pipes, fitting a new compressor, brazing, evacuating and recharging. - Replace outdoor temperature sensor (T3, T4, T5, T7)
Sensors are replaced in the outdoor unit. Check the sensor against the user interface before replacing it, because a bad PCB can also show a wrong tem - Replace refrigerant high pressure switch
The high pressure switch is brazed into the refrigerant line. Recover refrigerant before heating the joint. - Replace refrigerant pressure sensor
The pressure sensor is brazed into the refrigerant circuit. The refrigerant must be recovered first and fire precautions apply during brazing. - Sensor and valve functions on the outdoor unit
Quick reference for what each outdoor sensor and valve is used for. T3 is the outdoor coil temperature, used for high-temperature protection and outdo
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.