Secondary condensate protection above living space
What is going on
If the unit sits in or above a living space, protect against overflow water damage.
Likely causes
- Condensate overflow from the primary pan can cause water damage.
Check in this order
- Install a field-supplied external condensate pan under the whole unit, with a secondary drain line and trap run into it.
- Drain the external pan to a visible location.
- Alternatively, run a separate 3/4 in. (19 mm) secondary condensate line with trap where local code allows.
- Install a float switch to shut the unit off if water in the secondary pan rises too high.
- Tell the owner that the unit needs service if water flows from the secondary drain.
Applies to: Units in or above living spaces
More air conditioner guides
Take it to the job
All guides, error codes and tips work offline in the HVACopedia app.
Source: DLFULA Installation Instructions, pp. 15-16. Written in our own words; check the manual for your exact model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.