Charging a system with flammable refrigerant

D5FUHA

What is going on

Charging and leak-test steps for R454B / flammable refrigerant systems.

Check in this order

  1. Use only tools approved for flammable refrigerants.
  2. Keep charging hoses as short as possible.
  3. Make sure charging equipment does not contaminate refrigerants.
  4. Keep cylinders upright.
  5. Earth the refrigeration system before charging.
  6. Do not overfill the system.
  7. Pressure test with oxygen-free nitrogen (OFN) before recharging.
  8. Leak test after charging and before commissioning.
  9. Run a follow-up leak test before leaving the site.
  10. Label the system when charging is complete.

Applies to: Flammable refrigerant systems

More air conditioner guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Carrier D5FUHA installation instructions, p. 8. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.