Outdoor coil high-temperature protection (T3)

NAA

What is going on

If T3 goes above the maximum set temperature of 147 F (64 C), the unit stops and waits until T3 falls to the recovery point. The unit restarts when T3 drops below the set recovery temperature of 135 F (57 C).

Likely causes

  • Outdoor coil running too hot, often from poor airflow or heat load at the condenser

Check in this order

  1. Check outdoor coil and fan for blockage or poor airflow.
  2. Confirm T3 reading on the parameter check table.
  3. Restart is automatic once T3 falls below 135 F (57 C).

Applies to: NAA outdoor unit

More air conditioner guides

Take it to the job

All guides, error codes and tips work offline in the HVACopedia app.

Open the app

Source: Navien NAA air conditioner service manual, p. 17. Written in our own words; check the manual for your exact model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.