Navien boiler error codes
121 codes (45 faults, 76 normal display and menu codes), plus 2 settings tables.
| Code | Meaning | Severity / type |
|---|---|---|
| 2nd ignition - No. of Times | EMS Data counter 4 | Menu / mode display |
| 3rd ignition - No. of Times | EMS Data counter 5 | Menu / mode display |
| 4th ignition - No. of Times | EMS Data counter 6 | Menu / mode display |
| 5~10th ignition - No. of Times | EMS Data counter 7 | Menu / mode display |
| E001 | Heat exchanger overheat | High |
| E003 | Ignition failure | High |
| E004 | False flame detected | High |
| E012 | Flame loss | High |
| E016 | Heat exchanger overheat (check flow / system filters) | High |
| E020 | Abnormal Gas Control Valve | Critical |
| E030 | Exhaust overheat | High |
| E031 | Burner overheat | High |
| E046 | Heat exchanger thermistor fault | Medium |
| E047 | Exhaust thermistor fault | Medium |
| E060 | Dual venturi fault | Medium |
| E109 | Fan motor fault | High |
| E110 | Exhaust blockage | High |
| E123 | Abnormal Fan Motor Blower | High |
| E205 | Heating supply temperature sensor | Medium |
| E218 | Heating return temperature sensor | Medium |
| E278 | External system supply sensor not detected | Medium |
| E279 | External system return sensor not detected | Medium |
| E291 | Return temperature higher than supply | Medium |
| E302 | Low water pressure | High |
| E352 | High water pressure | High |
| E353 | Water pressure sensor fault | Medium |
| E407 | Dom. Hot Water Outlet Sensor | Medium |
| E421 | Dom. Cold Water Inlet Sensor | Medium |
| E434 | Abnormal Water Adjust Valve | Medium |
| E439 | No Dom. Water Flow Detected | Medium |
| E441 | Domestic hot water outlet 2 sensor fault | Medium |
| E445 | Abnormal mixing valve | High |
| E480 | DHW tank sensor not detected | Low |
| E515 | PCB fault | Medium |
| E517 | DIP switch setting fault | Medium |
| E593 | Abnormal panel key | High |
| E594 | EEPROM fault | Medium |
| E598 | RTC communication abnormality | High |
| E615 | Memory fault | Medium |
| E736 | Cascade communication fault | Medium |
| E740 | Outdoor sensor not detected | Medium |
| E761 | Pump aquastat not detected | Medium |
| E762 | Vent pipe not fully inserted (VID) | Critical |
| E773 | Wrong gas type detected | Medium |
| E777 | Low water cutoff activated | High |
| E782 | Front panel communication fault | Medium |
| E784 | Zone controller communication fault | Medium |
| E786 | Improper front panel detected | Medium |
| E788 | Incorrect gas type setting | High |
| SH1 Thermostat Status | Input/Output Status item 1 - SH1 Thermostat Status | Menu / mode display |
| SH2 Thermostat Status | Input/Output Status item 2 - SH2 Thermostat Status | Menu / mode display |
| SH3 Thermostat Status | Input/Output Status item 3 - SH3 Thermostat Status | Menu / mode display |
| Zone2 Pump Status | Input/Output Status item 7 - Zone2 Pump Status | Menu / mode display |
| AHU SH Set Temp | Status Information item 5 - AHU SH Set Temp | Menu / mode display |
| AHU connection icon | Air handler connection | Normal status |
| Air Handler Interface Output Status | Input/Output Status item 15 - Air Handler Interface Output Status | Menu / mode display |
| Approx. Boiler Flow | Status Information item 11 - Approx. Boiler Flow | Menu / mode display |
| Auto air purge icon | Auto air purge running | Normal status |
| Boiler Pump Status | Input/Output Status item 5 - Boiler Pump Status | Menu / mode display |
| Boost Interval Time | Status Information item 23 - Boost Interval Time | Menu / mode display |
| Cascade/Main icon | Cascade main unit | Normal status |
| Combustion icon | Burner combusting | Normal status |
| DHW Operation Time | Service Status Info item 2 - DHW Operation Time | Menu / mode display |
| DHW Priority Output Status | Input/Output Status item 16 - DHW Priority Output Status | Menu / mode display |
| DHW Set Temp | Status Information item 4 - DHW Set Temp | Menu / mode display |
| DHW Tank set Temp | Status Information item 12 - DHW Tank set Temp | Menu / mode display |
| DHW Thermostat Status | Input/Output Status item 4 - DHW Thermostat Status | Menu / mode display |
| DHW demand icon | DHW demand present | Normal status |
| DHW priority icon | DHW priority enabled | Normal status |
| DHW temperature | DHW temperature display | Normal status |
| DHW/Zone1 Pump Status | Input/Output Status item 6 - DHW/Zone1 Pump Status | Menu / mode display |
| Dual Venturi Status | Input/Output Status item 13 - Dual Venturi Status | Menu / mode display |
| EMS Data | EMS Data menu (history counters) | Menu / mode display |
| Elapsed Time After Install | EMS Data counter 1 | Menu / mode display |
| Error History | Error history list | Menu / mode display |
| Exhaust Temp | Status Information item 20 - Exhaust Temp | Menu / mode display |
| Fan Current APS | Status Information item 19 - Fan Current APS | Menu / mode display |
| Fan Current RPM | Status Information item 17 - Fan Current RPM | Menu / mode display |
| Fan Target APS | Status Information item 18 - Fan Target APS | Menu / mode display |
| Fan Target RPM | Status Information item 16 - Fan Target RPM | Menu / mode display |
| Flame Loss - No. of Times | EMS Data counter 3 | Menu / mode display |
| Flame Value | Status Information item 15 - Flame Value | Menu / mode display |
| Freeze Protection icon | Freeze protection mode active | Normal status |
| Gas | Status Information item 26 - Gas | Menu / mode display |
| Gas Consumption | Service Status Info item 3 - Gas Consumption | Menu / mode display |
| HEX Overheat - No. of Times | EMS Data counter 2 | Menu / mode display |
| HTL Input Status | Input/Output Status item 12 - HTL Input Status | Menu / mode display |
| Heat Capacity | Status Information item 2 - Heat Capacity | Menu / mode display |
| High Altitude | Status Information item 24 - High Altitude | Menu / mode display |
| LWCO Input Status | Input/Output Status item 14 - LWCO Input Status | Menu / mode display |
| Main F/W Ver | Status Information item 27 - Main F/W Ver | Menu / mode display |
| Main Menu | Main menu | Menu / mode display |
| Model | Status Information item 25 - Model | Menu / mode display |
| Operation State | Status Information item 1 - Operation State | Menu / mode display |
| Outdoor Reset | Status Information item 21 - Outdoor Reset | Menu / mode display |
| Outdoor Reset Curve | Status Information item 22 - Outdoor Reset Curve | Menu / mode display |
| Outdoor Temp | Status Information item 10 - Outdoor Temp | Menu / mode display |
| Outdoor reset icon | Outdoor reset enabled | Normal status |
| Outdoor temperature | Outdoor temperature display | Normal status |
| Panel F/W Ver | Status Information item 28 - Panel F/W Ver | Menu / mode display |
| Return Temp | Status Information item 7 - Return Temp | Menu / mode display |
| SH Operation Time | Service Status Info item 1 - SH Operation Time | Menu / mode display |
| SH Set Temp | Status Information item 3 - SH Set Temp | Menu / mode display |
| Service menu | Advanced / service menu (Back + Menu) | Menu / mode display |
| Space heating demand icon | Space heating demand | Normal status |
| Space heating temperature | Space heating temperature display | Normal status |
| Status Information | Status Information menu | Menu / mode display |
| Supply Limit - No. of Times | EMS Data counter 9 | Menu / mode display |
| Supply Temp | Status Information item 6 - Supply Temp | Menu / mode display |
| Sys Return Temp | Status Information item 9 - Sys Return Temp | Menu / mode display |
| Sys Supply Temp | Status Information item 8 - Sys Supply Temp | Menu / mode display |
| System check icon | System check or error needed | Normal status |
| System pressure | System pressure display | Normal status |
| Tank Sensor Temp | Status Information item 13 - Tank Sensor Temp | Menu / mode display |
| Water Press | Status Information item 14 - Water Press | Menu / mode display |
| Zone V/V 1 Status | Input/Output Status item 9 - Zone V/V 1 Status | Menu / mode display |
| Zone V/V 2 Status | Input/Output Status item 10 - Zone V/V 2 Status | Menu / mode display |
| Zone V/V 3 Status | Input/Output Status item 11 - Zone V/V 3 Status | Menu / mode display |
| system/Zone3 Pump Status | Input/Output Status item 8 - system/Zone3 Pump Status | Menu / mode display |
| △T High - No. of Times | EMS Data counter 10 | Menu / mode display |
| △T Limit - No. of Times | EMS Data counter 8 | Menu / mode display |
Settings and specs
Models covered
NFB-175HNFB-200HNHB-055HNHB-080HNHB-110HNHB-150H
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.