Navien · Boiler

E773 Wrong gas type detected

Medium severity NCB700

What the control is telling you

Warning shown when the boiler detects that the gas type it sees differs from the gas type set during installation. The check does not catch every bad gas connection, so the DIP switch setting must be verified before use. It can take some time to detect a mismatch, depending on gas flow and exhaust temperature. The code can also appear with the correct gas type set, because of normal measurement tolerances.

Applies to: NCB700 condensing combi-boiler

Likely causes

  • Gas type set on DIP switch 1 does not match the gas supply connected to the boiler
  • Gas type set during installation differs from the gas actually connected
  • Normal measurement tolerance in the unit, with the correct setting

Test and repair steps

  1. Check the rating plate for the gas type, gas pressure and supply details.
  2. Check that DIP switch 1 on the front panel matches the connected gas: OFF for natural gas, ON for propane.
  3. If the switch is correct for the connected gas and E773 stays on, contact Navien technical support.
  4. Do not run the boiler on a gas type other than the one on the rating plate.

Settings for these units

Other codes on the same units

  • E421 Dom. Cold Water Inlet Sensor
  • E434 Abnormal Water Adjust Valve
  • E439 No Dom. Water Flow Detected
  • E441 Domestic hot water outlet 2 sensor fault
  • E445 Abnormal mixing valve
  • E593 Abnormal panel key
  • E598 RTC communication abnormality
  • E761 Pump aquastat not detected

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NCB700 installation and operation manual, p. 62. Summarized in our own words; check the original manual for your model.

Homeowner looking at this code? See what it means for you and when to call a technician.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.