Navien · Boiler
△T Limit - No. of Times EMS Data counter 8
What the display is showing
History counter: number of times supply/return temperature difference limit control has acted. Read-only information in the EMS Data list (item 8).
Applies to: NHB-055H, NHB-080H, NHB-110H, NHB-150H
What to do
- Menu > 5. EMS Data > scroll to the item.
Settings for these units
Installation clearances (indoor) · Navien NHB-H
| Side | Minimum clearance |
|---|---|
| Top | 9 in (229 mm) |
| Back | 0.5 in (13 mm) |
| Front | 4 in (100 mm) |
| Sides | 3 in (76 mm) |
| Bottom | 12 in (300 mm) |
| Vent to combustibles | 0 in |
Bracket gives 5/8 in (16 mm) from the wall; studs at 16 in on centre.
Common vent installs: 36 in above the top and 24 in in front are recommended for service.
Models that show this code
4 models in Navien NHB-H
Other codes on the same units
- System pressure System pressure display
- Tank Sensor Temp Status Information item 13 - Tank Sensor Temp
- Water Press Status Information item 14 - Water Press
- Zone V/V 1 Status Input/Output Status item 9 - Zone V/V 1 Status
- Zone V/V 2 Status Input/Output Status item 10 - Zone V/V 2 Status
- Zone V/V 3 Status Input/Output Status item 11 - Zone V/V 3 Status
- system/Zone3 Pump Status Input/Output Status item 8 - system/Zone3 Pump Status
- △T High - No. of Times EMS Data counter 10
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NHB-H Installation and Operation Manual, 11.11, p.108-109. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.