Navien · Boiler

SH2 Thermostat Status Input/Output Status item 2 - SH2 Thermostat Status

Menu / mode display Navien NHB-H

What the display is showing

Service menu 2. Input/Output Status, item 2: shows the state of the space heating thermostat 2 input. Useful to see whether the control is seeing or sending a signal.

Applies to: NHB-055H, NHB-080H, NHB-110H, NHB-150H

What to do

  1. Hold Back + Menu 3 s > 2. Input/Output Status > pick the item.

Settings for these units

Installation clearances (indoor) · Navien NHB-H

SideMinimum clearance
Top9 in (229 mm)
Back0.5 in (13 mm)
Front4 in (100 mm)
Sides3 in (76 mm)
Bottom12 in (300 mm)
Vent to combustibles0 in

Bracket gives 5/8 in (16 mm) from the wall; studs at 16 in on centre.

Common vent installs: 36 in above the top and 24 in in front are recommended for service.

Models that show this code

4 models in Navien NHB-H

NHB-055HNHB-080HNHB-110HNHB-150H

Other codes on the same units

Save it for the next call

Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.

Open the app

Source: Navien NHB-H Installation and Operation Manual, 11.13.2 Viewing Input and Output Status, p.110-111. Summarized in our own words; check the original manual for your model.

For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.