Navien · Boiler
Approx. Boiler Flow Status Information item 11 - Approx. Boiler Flow
What the display is showing
Approximate flow rate (GPM). Read-only item 11 in the Status Information menu.
Applies to: NHB-055H, NHB-080H, NHB-110H, NHB-150H
What to do
- Menu > 1. Status Information > scroll to the item.
Settings for these units
Installation clearances (indoor) · Navien NHB-H
| Side | Minimum clearance |
|---|---|
| Top | 9 in (229 mm) |
| Back | 0.5 in (13 mm) |
| Front | 4 in (100 mm) |
| Sides | 3 in (76 mm) |
| Bottom | 12 in (300 mm) |
| Vent to combustibles | 0 in |
Bracket gives 5/8 in (16 mm) from the wall; studs at 16 in on centre.
Common vent installs: 36 in above the top and 24 in in front are recommended for service.
Models that show this code
4 models in Navien NHB-H
Other codes on the same units
- Zone2 Pump Status Input/Output Status item 7 - Zone2 Pump Status
- AHU SH Set Temp Status Information item 5 - AHU SH Set Temp
- AHU connection icon Air handler connection
- Air Handler Interface Output Status Input/Output Status item 15 - Air Handler Interface Output Status
- Auto air purge icon Auto air purge running
- Boiler Pump Status Input/Output Status item 5 - Boiler Pump Status
- Boost Interval Time Status Information item 23 - Boost Interval Time
- Cascade/Main icon Cascade main unit
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NHB-H User's Information Manual (V1.0 Apr 2024), 3.3, p.13-14; Navien NHB-H Installation and Operation Manual, 11.7, p.103-104. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.