Navien · Boiler
Service menu Advanced / service menu (Back + Menu)
What the display is showing
Hidden advanced menu opened by holding Back and Menu together for 3 seconds: 1. Service Status Info, 2. Input/Output Status, 3. Parameter Settings (password screen, factory password in the manual).
Applies to: NHB-055H, NHB-080H, NHB-110H, NHB-150H
What to do
- Hold Back and Menu together for 3 seconds.
- Choose an entry with the Command dial.
- Press Back to return.
Settings for these units
Installation clearances (indoor) · Navien NHB-H
| Side | Minimum clearance |
|---|---|
| Top | 9 in (229 mm) |
| Back | 0.5 in (13 mm) |
| Front | 4 in (100 mm) |
| Sides | 3 in (76 mm) |
| Bottom | 12 in (300 mm) |
| Vent to combustibles | 0 in |
Bracket gives 5/8 in (16 mm) from the wall; studs at 16 in on centre.
Common vent installs: 36 in above the top and 24 in in front are recommended for service.
Models that show this code
4 models in Navien NHB-H
Other codes on the same units
- Panel F/W Ver Status Information item 28 - Panel F/W Ver
- Return Temp Status Information item 7 - Return Temp
- SH Operation Time Service Status Info item 1 - SH Operation Time
- SH Set Temp Status Information item 3 - SH Set Temp
- Space heating demand icon Space heating demand
- Space heating temperature Space heating temperature display
- Status Information Status Information menu
- Supply Limit - No. of Times EMS Data counter 9
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NHB-H Installation and Operation Manual, 11.13 Accessing Advanced Menu Items, p.109-111. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.