Navien · Boiler
Outdoor Reset Curve Status Information item 22 - Outdoor Reset Curve
What the display is showing
Load type used by outdoor reset (shown only when outdoor reset is enabled): 1 finned tube baseboard, 2 fan coil, 3 cast iron baseboard, 4 low mass radiant, 5 high mass radiant, 6 radiator, 7 custom (installer set). Read-only item 22 in the Status Information menu.
Applies to: NHB-055H, NHB-080H, NHB-110H, NHB-150H
What to do
- Menu > 1. Status Information > scroll to the item.
Settings for these units
Installation clearances (indoor) · Navien NHB-H
| Side | Minimum clearance |
|---|---|
| Top | 9 in (229 mm) |
| Back | 0.5 in (13 mm) |
| Front | 4 in (100 mm) |
| Sides | 3 in (76 mm) |
| Bottom | 12 in (300 mm) |
| Vent to combustibles | 0 in |
Bracket gives 5/8 in (16 mm) from the wall; studs at 16 in on centre.
Common vent installs: 36 in above the top and 24 in in front are recommended for service.
Models that show this code
4 models in Navien NHB-H
Other codes on the same units
- Main Menu Main menu
- Model Status Information item 25 - Model
- Operation State Status Information item 1 - Operation State
- Outdoor Reset Status Information item 21 - Outdoor Reset
- Outdoor Temp Status Information item 10 - Outdoor Temp
- Outdoor reset icon Outdoor reset enabled
- Outdoor temperature Outdoor temperature display
- Panel F/W Ver Status Information item 28 - Panel F/W Ver
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NHB-H User's Information Manual (V1.0 Apr 2024), 3.3, p.13-14; Navien NHB-H Installation and Operation Manual, 11.7, p.103-104. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.