Navien · Boiler
DHW/Zone1 Pump Status Input/Output Status item 6 - DHW/Zone1 Pump Status
What the display is showing
Service menu 2. Input/Output Status, item 6: shows the state of the DHW / zone 1 pump output. Useful to see whether the control is seeing or sending a signal.
Applies to: NHB-055H, NHB-080H, NHB-110H, NHB-150H
What to do
- Hold Back + Menu 3 s > 2. Input/Output Status > pick the item.
Settings for these units
Installation clearances (indoor) · Navien NHB-H
| Side | Minimum clearance |
|---|---|
| Top | 9 in (229 mm) |
| Back | 0.5 in (13 mm) |
| Front | 4 in (100 mm) |
| Sides | 3 in (76 mm) |
| Bottom | 12 in (300 mm) |
| Vent to combustibles | 0 in |
Bracket gives 5/8 in (16 mm) from the wall; studs at 16 in on centre.
Common vent installs: 36 in above the top and 24 in in front are recommended for service.
Models that show this code
4 models in Navien NHB-H
Other codes on the same units
- DHW Thermostat Status Input/Output Status item 4 - DHW Thermostat Status
- DHW demand icon DHW demand present
- DHW priority icon DHW priority enabled
- DHW temperature DHW temperature display
- Dual Venturi Status Input/Output Status item 13 - Dual Venturi Status
- EMS Data EMS Data menu (history counters)
- Elapsed Time After Install EMS Data counter 1
- Error History Error history list
Save it for the next call
Star this code in the HVACopedia app and keep the whole library on your phone for jobs with no signal.
Source: Navien NHB-H Installation and Operation Manual, 11.13.2 Viewing Input and Output Status, p.110-111. Summarized in our own words; check the original manual for your model.
For licensed technicians. Gas, electrical and refrigerant work must be done by a qualified, licensed person. Shut off power and gas before servicing, never bypass a safety control, and follow the manufacturer’s manual for the exact model; it and local codes always take priority. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.