OEM part number

0010 Electrical Box

Viessmann part 0010 (Fuse, Inst/Oper/Svc Instr Vitocell MSCA, Anode Control Module, Leveling bolts (accessory pack), Ionization electrode block with gasket, Cable inlet grommets (2 pcs), Flue duct and gaskets, Gasket set pipework, Air box hydraulics gasket (4 pcs), Support bracket, right, Burner mounting flange assembly, Nameplate, Burner door assembly, Vent pipe adaptor, Connecting pipe for tank DCW, Control panel (wired), 120/1/60, Connecting cable for emissions test switch). Listed for 68 models below.

Viessmann Vitocal 100-AW

Electrical Box. Fits 1 of 7 models:

Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 104, page 104. Full Vitocal 100-AW parts list

Viessmann Vitocal 100-WA

Fuse · 5 A. Fits 5 of 5 models:

Not shown in diagram

Source: Vitocal 100-WA installation, service and operating manual, p. 80, page 80. Full Vitocal 100-WA parts list

Viessmann Vitocell 100-E

Inst/Oper/Svc Instr Vitocell MSCA. Fits 1 of 3 models:

Source: Vitocell 100-E MSCA-20-S2 installation, service and operating instructions, p. 17, page 17. Full Vitocell 100-E parts list

Viessmann Vitocell 100-V CVWC

Anode Control Module. Fits 1 of 3 models:

Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, page 31. Full Vitocell 100-V CVWC parts list

Viessmann Vitocell 100-V CVWC

Anode Control Module. Fits 2 of 3 models:

Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, page 32. Full Vitocell 100-V CVWC parts list

Viessmann Vitocrossal 200 CM2

Leveling bolts (accessory pack). Fits 3 of 20 models:

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 54. Full Vitocrossal 200 CM2 parts list

Viessmann Vitocrossal 200 CM2

Ionization electrode block with gasket. Fits 1 of 20 models:

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 57. Full Vitocrossal 200 CM2 parts list

Viessmann Vitocrossal 200 CM2

Ionization electrode block with gasket. Fits 3 of 20 models:

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 58. Full Vitocrossal 200 CM2 parts list

Viessmann Vitocrossal 300 CA3B Dual Fuel

Fuse · Qty Set of 10 · 2.0A/250V. Fits 1 of 43 models:

Sold as a set of 10

Source: Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0 Service, p. 152, page 152. Full Vitocrossal 300 CA3B Dual Fuel parts list

Viessmann Vitodens 100-W B1HE/B1KE

Cable inlet grommets (2 pcs) · Qty 2. Fits 6 of 6 models:

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 107. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 100-W B1HE/B1KE

Flue duct and gaskets. Fits 3 of 6 models:

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 108. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 100-W B1HE/B1KE

Gasket set pipework. Fits 3 of 6 models:

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 109. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 100-W B1HE/B1KE

Air box hydraulics gasket (4 pcs) · Qty 4. Fits 2 of 6 models:

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 112. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 200-W

Support bracket, right. Fits 4 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 94. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Burner mounting flange assembly. Fits 4 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Nameplate. Fits 6 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 94. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Burner door assembly. Fits 3 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 97. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Nameplate. Fits 4 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 98. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Support bracket, right. Fits 3 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 95. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W B2HA

Vent pipe adaptor · 110/150. Fits 3 of 13 models:

Source: Vitodens 200-W B2HA 45, 60 Service Instructions, page 96. Full Vitodens 200-W B2HA parts list

Viessmann Vitodens 200-W B2HA

Support bracket, right. Fits 2 of 13 models:

Source: Vitodens 200-W B2HA 45, 60 Service Instructions, page 89. Full Vitodens 200-W B2HA parts list

Viessmann Vitotronic 200-H

Control panel (wired), 120/1/60 · 120/1/60. Fits 1 of 13 models:

Position number

Source: Vitotronic 200-H installation and service manual, p. 69, page 79. Full Vitotronic 200-H parts list

Viessmann Vitotronic 300

Connecting cable for emissions test switch. Fits 1 of 23 models:

Source: Vitotronic 300, GW6B installation and service instructions, p. 123, page 123. Full Vitotronic 300 parts list

Viessmann Vitotronic 300-K

Connecting cable for emissions test switch. Fits 1 of 4 models:

Source: Vitotronic 200 and 300-K Installation and Service Instructions, p. 94, page 94. Full Vitotronic 300-K parts list

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.