Viessmann · Boiler parts

Viessmann Vitotronic 200-H: parts list

103 replacement parts with OEM part numbers for 13 models. Pick your model for a list of only the parts that fit it.

Jump to: Electrical · Other

Electrical

PartPart #FitsQtySize / rating
Fuse020HK1M14.0 A
Screw cap for fuse024HK1M1
Circuit board, control software035HK1M1
Motherboard, 120V052HK1M1120V
Harness for programming unit074HK1M1

Other

PartPart #FitsQtySize / rating
Power supply module A1
Fuse F1 replacement is on this module.
7189 737Not stated1Fuse F1: 4 A time delay
Electronic module A2 (microprocessor with software)
After replacing the PC board, set code 8A:176 and coding 92 (see replacement guide).
7820 788HK1S and HK3S1
Power module A3 (relays for mixing valve motor and heating circuit pumps)7158 003Not stated1
Extension module A47189 828HK3S only1
Programming unit A5 (user interface)
Part numbers are listed in a table with Typ HK1S and Typ HK3S columns; the exact pairing is not clear from the page.
7143 439 / 7143 442 / 7143 440 / 7143 443 / 7820 171 / 7820 170HK1S and HK3S1
Front plate7818 630HK1S only1
Front plate7818 623HK3S only1
Hinge001HK1S, HK3S1
Support stay008HK1S, HK3S1
Programming unit ON/OFF switch011HK1S, HK3S1
Housing front with frame (with item 001)013HK1S, HK3S1
PCB cover014HK1S, HK3S1
Front flap015HK1S, HK3S1
Casing back016HK1S, HK3S1
Mounting panel017HK1S, HK3S1
Programming unit018HK1S, HK3S1
Programming unit flap019HK1S, HK3S1
Fascia cover020HK1S, HK3S1
Ribbon cable, 14-pole
Only for model HK3S
021HK3S1
Fuse holder cap for control fuse024HK1S, HK3S1
Fuse holder for control fuse025HK1S, HK3S1
Switch, 2-pole (ON/OFF switch "8")038HK1S, HK3S1
Outdoor temperature sensor040HK1S, HK3S1
DHW tank temperature sensor with plug043HK1S, HK3S1
LON communication module047HK1S, HK3S1
Electronics PCB mixing valve extension
Only for model HK3S
048HK3S1
Main PCB low voltage049HK1S, HK3S1
Electronics PCB050HK1S, HK3S1
Optolink051HK1S, HK3S1
Main PCB 230 V~052HK1S, HK3S1
Power supply unit PCB054HK1S, HK3S1
Mixing valve extension PCB
Only for model HK3S
055HK3S1
Viessmann 2-wire BUS communication module056HK1S, HK3S1
Immersion temperature sensor067HK1S, HK3S1
Contact temperature sensor068HK1S, HK3S1
Connecting cable074HK1S, HK3S1
Fuse (slow)
Slow-blow
092HK1S, HK3S16.3 A/250 V~
LON connecting cable
Parts not shown in the diagram
093HK1S, HK3S1
Terminator
Parts not shown in the diagram
094HK1S, HK3S2 pieces
Plugs for sensors
Parts not shown in the diagram
100HK1S, HK3S3 pieces
Plugs for pumps
Parts not shown in the diagram
101HK1S, HK3S3 pieces
Plugs gS
Parts not shown in the diagram
102HK1S, HK3S3 pieces
Plugs aBH
Parts not shown in the diagram
103HK1S, HK3S3 pieces
Mains supply plugs fÖ
Parts not shown in the diagram
104HK1S, HK3S3 pieces
Plugs gÖ
Parts not shown in the diagram
106HK1S, HK3S3 pieces
Plug aVD, plug aVG and plug aVH
Parts not shown in the diagram
108HK1S, HK3S1
Actuator kit for one mixing valve controller
Default rotary dial position 4 on wall-mounted boilers
7133 392HK1M1
Actuator kit for one mixing valve controller
Default rotary dial position is 4 when this kit is used
7133 392Vitotronic 200-H, wall-mounted boilers1
Vitotrol 200 remote control
With integral room temperature sensor for mixing valve circuit; 2-wire connection
7133 378Vitotronic 200-H HK1M1
Room temperature sensor
Separate room sensor when remote control cannot be installed in a suitable place
7133 379Vitotronic 200-H HK1M1
Transparent cover001HK1M1
Connection cover006HK1M1
Control console011HK1M1
Programming unit025HK1M1
Accessory pack, strain reliefs036HK1M1
Strain relief037HK1M1
Strain relief for communication module038HK1M1
Support for communication module039HK1M1
Communication module, LON097HK1M1
Communication module, 2-wire BUS098HK1M1
Installation Instructions080HK1M1
Operating Instructions081HK1M1
Parts List082HK1M1
Accessory pack, low voltage plugs100HK1M1
Power/Pump Ctrl Module, HK1M200HK1M1
Mounting screw set019HK1M1
Sensor #2, strap-on with cable034HK1M1
Sensor #1, outdoor040HK1M1
LON terminal resistor049HK1M2 pieces
Connecting cable, 2-wire BUS072HK1M15 m / 16 ft
Extension cable, 2-wire BUS073HK1M16 m / 19.5 ft
Connecting cable, LON RJ45078HK1M17 m / 23 ft
Handle for mixing valve motor079HK1M1
Base plate092HK1M1
Motor drive, 120V094HK1M1120V
Connecting cable, 2-wire BUS099HK1M10.8 m / 2.5 ft
Housing, front
Position number from parts list
0001HK1B1
Hinges for control housing (set of 2)
Position number
0002HK1B1
Support arm
Position number
0003HK1B1
Flip-down cover
Position number
0004HK1B1
Cover, left KR
Position number
0005HK1B1
Cover, right with fuse
Position number
0006HK1B1
Circuit boards, Optolink, SA142/143
Position number
0007HK1B1
Flat cable, 10-pole
Position number
0008HK1B110-pole
Flat cable, 16-pole
Position number
0009HK1B116-pole
Accessory pack, low voltage plugs
Position number
0013HK1B1
3-Pole plug, male, #20 (set of 3)
Position number
0014HK1B1
4-Pole plug, #52 (set of 3)
Position number
0015HK1B1
3-Pole plug, #156 (set of 3)
Position number
0016HK1B1
3-Pole plug, #40 (set of 3)
Position number
0017HK1B1
3-Pole plug, #50 (set of 3)
Position number
0019HK1B1
Accessory pack, plugs #143, #145, and #146
Position number
0020HK1B1
Control panel (wired), 120/1/60
Position number
0010HK1B1120/1/60
DHW immersion sensor, NTC
Position number
0021HK1B1NTC
Strap-on supply temperature sensor, NTC
Position number
0022HK1B1NTC
LON connecting cable, 23 ft / 7 m
Position number
0026HK1B123 ft / 7 m
LON terminal resistor (set of 2)
Position number
0027HK1B1
Extension module MV 2+3
Other part, not illustrated
0350HK1B1

Source: Vitotronic 200-H installation and service manual, p. 69 (pages 16, 36, 37, 39, 53, 54, 69, 78, 79). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.