OEM part number
0008 Air to Refrigerant Coil
Viessmann part 0008 (1 to c in. Reducing Elbow Brass, Relay, Plug, Top Panel, Air filter, filter box, Boiler temperature sensor well, Ignition transformer, Terminal block, PT 16, Ventilation cover, Flue gas sensor, Grommet DN80, Cover panel, Radial fan, Sealing grommet, DN60, Condensate hose 1, Gas distribution pipe 2, Retaining clip (set of 5), Flat cable, 10-pole). Listed for 72 models below.
Viessmann Vitocal 100-AW
Air to Refrigerant Coil. Fits 1 of 7 models:
Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 104, page 104. Full Vitocal 100-AW parts list
Viessmann Vitocal 100-AW
1 to c in. Reducing Elbow Brass. Fits 3 of 7 models:
Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 104, page 106. Full Vitocal 100-AW parts list
Viessmann Vitocal 100-WA
Relay. Fits 5 of 5 models:
Source: Vitocal 100-WA installation, service and operating manual, p. 80, page 80. Full Vitocal 100-WA parts list
Viessmann Vitocell 100-E
Plug. Fits 1 of 3 models:
Source: Vitocell 100-E MSCA-20-S2 installation, service and operating instructions, p. 17, page 17. Full Vitocell 100-E parts list
Viessmann Vitocell 100-V CVWC
Top Panel. Fits 1 of 3 models:
Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, page 31. Full Vitocell 100-V CVWC parts list
Viessmann Vitocell 100-V CVWC
Top Panel. Fits 2 of 3 models:
Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, page 32. Full Vitocell 100-V CVWC parts list
Viessmann Vitocrossal 200 CI2
Air filter, filter box. Fits 2 of 21 models:
Source: Vitocrossal 200 CI2 service instructions, p. 130, page 130. Full Vitocrossal 200 CI2 parts list
Viessmann Vitocrossal 200 CM2
Boiler temperature sensor well. Fits 3 of 20 models:
Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 54. Full Vitocrossal 200 CM2 parts list
Viessmann Vitocrossal 200 CM2
Ignition transformer. Fits 1 of 20 models:
Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 57. Full Vitocrossal 200 CM2 parts list
Viessmann Vitocrossal 200 CM2
Ignition transformer. Fits 3 of 20 models:
Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 58. Full Vitocrossal 200 CM2 parts list
Viessmann Vitocrossal 300 CA3B Dual Fuel
Terminal block, PT 16 · PT 16. Fits 1 of 43 models:
Source: Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0 Service, p. 152, page 152. Full Vitocrossal 300 CA3B Dual Fuel parts list
Viessmann Vitodens 100-W B1HE/B1KE
Ventilation cover. Fits 6 of 6 models:
Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 107. Full Vitodens 100-W B1HE/B1KE parts list
Viessmann Vitodens 100-W B1HE/B1KE
Flue gas sensor. Fits 3 of 6 models:
Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 108. Full Vitodens 100-W B1HE/B1KE parts list
Viessmann Vitodens 100-W B1HE/B1KE
Grommet DN80 · DN80. Fits 3 of 6 models:
Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 109. Full Vitodens 100-W B1HE/B1KE parts list
Viessmann Vitodens 200-W
Cover panel. Fits 4 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 94. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Radial fan · RG148, 120/1/60. Fits 4 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Sealing grommet, DN60 · DN60. Fits 6 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 94. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Condensate hose 1. Fits 3 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Cover panel. Fits 4 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 98. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Cover panel. Fits 3 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 95. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W B2HA
Gas distribution pipe 2. Fits 3 of 13 models:
Source: Vitodens 200-W B2HA 45, 60 Service Instructions, page 96. Full Vitodens 200-W B2HA parts list
Viessmann Vitodens 200-W B2HA
Cover panel. Fits 2 of 13 models:
Source: Vitodens 200-W B2HA 45, 60 Service Instructions, page 89. Full Vitodens 200-W B2HA parts list
Viessmann Vitodens 222-F
Retaining clip (set of 5) · Qty 5. Fits all 19 models in the series:
Source: Vitodens 222-F B2TB service instructions, p. 106, page 104. Full Vitodens 222-F parts list
Viessmann Vitotronic 200-H
Flat cable, 10-pole · 10-pole. Fits 1 of 13 models:
Position number
Source: Vitotronic 200-H installation and service manual, p. 69, page 78. Full Vitotronic 200-H parts list
Viessmann Vitotronic 300
Flat cable, 10-pole · 10-pole. Fits 1 of 23 models:
Source: Vitotronic 300, GW6B installation and service instructions, p. 123, page 123. Full Vitotronic 300 parts list
Viessmann Vitotronic 300-K
Flat cable, 10-pole · 10-pole. Fits 1 of 4 models:
Source: Vitotronic 200 and 300-K Installation and Service Instructions, p. 94, page 94. Full Vitotronic 300-K parts list
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.