Viessmann Vitocal 100-AW: parts list

62 replacement parts with OEM part numbers for 7 models. Pick your model for a list of only the parts that fit it.

Jump to: Other

Other

PartPart #FitsQtySize / rating
Fan Grill0001AM2V 0510781
Front Panel0002AM2V 0510781
Wind Deflector0003AM2V 0510781
Fan Blade0004AM2V 0510781
Fan Motor0005AM2V 0510781
Left Panel0006AM2V 0510781
Corner Panel0007AM2V 0510781
Air to Refrigerant Coil0008AM2V 0510781
Fan Motor Bracket0009AM2V 0510781
Electrical Box0010AM2V 0510781
Top Panel0011AM2V 0510781
Top Rail0012AM2V 0510781
Electrical Box Cover0013AM2V 0510781
Rear Grill Panel0014AM2V 0510781
Interior Separation Panel0015AM2V 0510781
Refrigerant to System Water Plate Heat Exchanger0016AM2V 0510781
System Water Supply Pipe0017AM2V 0510781
System Water Return Pipe0018AM2V 0510781
Refrigerant to System Water Plate Heat Exchanger Bracket0019AM2V 0510781
Reversing Valve0020AM2V 0510781
Transformer0021AM2V 0510781
System Water Flow Switch0022AM2V 0510781
Electrical Grommet0023AM2V 0510781
Side Access Panel0024AM2V 0510781
Rear Connections Panel0025AM2V 0510781
Support Bracket0026AM2V 0510781
Isolation Fill Valve0027AM2V 0510781
High Pressure Switch0028AM2V 0510781
Low Pressure Switch0029AM2V 0510781
One Way Safety Valve0030AM2V 0510781
Electronic Expansion Valve0031AM2V 0510781
Filter0032AM2V 0510781
Electronic Expansion Valve0033AM2V 0510781
Schrader Valve 10034AM2V 0510781
Schrader Valve 20035AM2V 0510781
EVI Plate Heat Exchanger0036AM2V 0510781
EVI Plate Heat Exchanger Bracket0037AM2V 0510781
Bracket0038AM2V 0510781
Compressor0039AM2V 0510781
Compressor Cover 10040AM2V 0510781
Base Plate0041AM2V 0510781
Compressor Cover 20042AM2V 0510781
Compressor Cover 30043AM2V 0510781
Compressor Cover 40044AM2V 0510781
Transformer0045AM2V 0510781
Transformer Cover0046AM2V 0510781
Transformer Base0047AM2V 0510781
Mounting Bracket0048AM2V 0510781
Suspension Chassis0049AM2V 0510781
Pressure Switch0050AM2V 0510781
Tee Fitting (9.7X9.7)0051AM2V 05107819.7X9.7
Tee Fitting (12.7X12.7)0052AM2V 051078112.7X12.7
Filter0053AM2V 0510781
Reducer 1-a to 1 in. Brass0001AM2V 020028, AM2V 034043, AM2V 0510781
1 in. Close Nipple Brass0002AM2V 020028, AM2V 034043, AM2V 0510781
Isolation Valve0003AM2V 020028, AM2V 034043, AM2V 0510781
1-a X 1 X 1 in. Reducing Tee Brass0004AM2V 020028, AM2V 034043, AM2V 0510781
Pressure Relief Valve 30 PSI0005AM2V 020028, AM2V 034043, AM2V 051078130 PSI
c in. Close Nipple Brass0006AM2V 020028, AM2V 034043, AM2V 0510781
1 in. X 6 in. Long Nipple Brass0007AM2V 020028, AM2V 034043, AM2V 0510781
1 to c in. Reducing Elbow Brass0008AM2V 020028, AM2V 034043, AM2V 0510781
Changeover Relay
Not shown in diagram
0009AM2V 020028, AM2V 034043, AM2V 0510781

Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 104 (pages 104, 106). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.