OEM part number
0020 Reversing Valve
Viessmann part 0020 (Adaptor NPT1” indirect coil, Plug 1¼”, Guide rail, top, left, Servomotor STA 120V, Relay module, O-ring (5 pcs), O-ring, Sight glass, Burner assembly, Power/pump control module, O-ring 24x2.5 mm (set of 5), O-Ring (Set of 5), Accessory pack, plugs #143, #145, and #146, Accessory pack (plugs #143, 145, 146)). Listed for 41 models below.
Viessmann Vitocal 100-AW
Reversing Valve. Fits 1 of 7 models:
Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 104, page 104. Full Vitocal 100-AW parts list
Viessmann Vitocell 100-V CVWC
Adaptor NPT1” indirect coil · NPT 1 in. Fits 1 of 3 models:
Indirect coil adaptor
Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, page 31. Full Vitocell 100-V CVWC parts list
Viessmann Vitocell 100-V CVWC
Plug 1¼” · 1¼ in. Fits 2 of 3 models:
Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, page 32. Full Vitocell 100-V CVWC parts list
Viessmann Vitocrossal 200 CM2
Guide rail, top, left. Fits 3 of 20 models:
Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 55. Full Vitocrossal 200 CM2 parts list
Viessmann Vitocrossal 200 CM2
Servomotor STA 120V · 120V. Fits 3 of 20 models:
Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 58. Full Vitocrossal 200 CM2 parts list
Viessmann Vitocrossal 300 CA3B Dual Fuel
Relay module · 120V DC 6 A. Fits 1 of 43 models:
Source: Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0 Service, p. 152, page 152. Full Vitocrossal 300 CA3B Dual Fuel parts list
Viessmann Vitodens 100-W B1HE/B1KE
O-ring (5 pcs) · Qty 5. Fits 2 of 6 models:
Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 112. Full Vitodens 100-W B1HE/B1KE parts list
Viessmann Vitodens 200-W
O-ring · Qty set of 5 · 24 x 2.5 mm. Fits 4 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 95. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Sight glass. Fits 4 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Burner assembly. Fits 6 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Burner assembly. Fits 3 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Power/pump control module. Fits 4 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 101. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
O-ring 24x2.5 mm (set of 5) · 24x2.5 mm. Fits 3 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W B2HA
O-ring · Qty set of 5 · 24x2.5 mm. Fits 3 of 13 models:
Source: Vitodens 200-W B2HA 45, 60 Service Instructions, page 96. Full Vitodens 200-W B2HA parts list
Viessmann Vitodens 200-W B2HA
O-Ring (Set of 5) · Qty Set of 5 · 24x2.5mm. Fits 2 of 13 models:
Source: Vitodens 200-W B2HA 45, 60 Service Instructions, page 90. Full Vitodens 200-W B2HA parts list
Viessmann Vitotronic 200-H
Accessory pack, plugs #143, #145, and #146. Fits 1 of 13 models:
Position number
Source: Vitotronic 200-H installation and service manual, p. 69, page 78. Full Vitotronic 200-H parts list
Viessmann Vitotronic 300
Accessory pack (plugs #143, 145, 146). Fits 1 of 23 models:
Source: Vitotronic 300, GW6B installation and service instructions, p. 123, page 123. Full Vitotronic 300 parts list
Viessmann Vitotronic 300-K
Accessory pack (plugs #143, 145, 146). Fits 1 of 4 models:
Source: Vitotronic 200 and 300-K Installation and Service Instructions, p. 94, page 94. Full Vitotronic 300-K parts list
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.