Viessmann Vitocrossal 200 CM2: parts list

150 replacement parts with OEM part numbers for 20 models. Pick your model for a list of only the parts that fit it.

Jump to: Other

Other

PartPart #FitsQtySize / rating
CM2 burner coding card, model 186
Match to burner control per commissioning chart
78423111861
CM2 burner coding card, model 246
Match to burner control per commissioning chart
78423122461
CM2 burner coding card, model 311
Match to burner control per commissioning chart
78423133111
Flue gas collector (PPS) with gasket0001CM2 186, CM2 246, CM2 3111
Gasket for flue gas collector0002CM2 186, CM2 246, CM2 3111
Connector with gasket0003CM2 186, CM2 246, CM2 3111
Gasket for connector0004CM2 186, CM2 246, CM2 3111
Condensate siphon0005CM2 186, CM2 246, CM2 3111
Flue gas sensor well0006CM2 186, CM2 246, CM2 3111
Flue gas vent adaptor with clamps0007CM2 186, CM2 246, CM2 3111
Boiler temperature sensor well0008CM2 186, CM2 246, CM2 3111
Boiler inspection cup 3 in.0009CM2 186, CM2 246, CM2 31113 in.
Leveling bolts (accessory pack)0010CM2 186, CM2 246, CM2 3111
Boiler door hinge bracket0011CM2 186, CM2 246, CM2 3111
Installation set0400CM2 186, CM2 246, CM2 3111
Electrical junction box with all necessary wiring harness
See p. 59
0500CM2 186, CM2 246, CM2 3111
Air intake kit0600CM2 186, CM2 246, CM2 3111
Bottom panel0012CM2 186, CM2 246, CM2 3111
Top panel, right0013CM2 186, CM2 246, CM2 3111
Top panel, left0014CM2 186, CM2 246, CM2 3111
Rear panel, top (with cover edge molding)0015CM2 186, CM2 246, CM2 3111
Cover edge molding0016CM2 186, CM2 246, CM2 3111
Rear panel, middle0017CM2 186, CM2 246, CM2 3111
Rear panel, bottom0018CM2 186, CM2 246, CM2 3111
Guide rail, top, right0019CM2 186, CM2 246, CM2 3111
Guide rail, top, left0020CM2 186, CM2 246, CM2 3111
Guide rail, bottom, left0021CM2 186, CM2 246, CM2 3111
Guide rail, bottom, right0022CM2 186, CM2 246, CM2 3111
Insulation blanket0023CM2 186, CM2 246, CM2 3111
Insulation blanket, front0024CM2 186, CM2 246, CM2 3111
Fasteners (accessory pack for insulation)0025CM2 186, CM2 246, CM2 3111
Front panel spring clip0026CM2 186, CM2 246, CM2 3111
Touch-up spray paint, silver0030CM2 186, CM2 246, CM2 3111
Touch-up paint stick, silver0031CM2 186, CM2 246, CM2 3111
Accessory pack, small parts for insulation0032CM2 186, CM2 246, CM2 3111
Pressure relief valve, 75 psi0401CM2 186, CM2 246, CM2 311175 psi
Nipple0402CM2 186, CM2 246, CM2 3111
90 degree street elbow0403CM2 186, CM2 246, CM2 3111
Hex bushing0404CM2 186, CM2 246, CM2 3111
Cross, 1 1/4 in.0405CM2 186, CM2 246, CM2 31111 1/4 in.
Tee0406CM2 186, CM2 246, CM2 3111
Cross, 1 1/4 in.0407CM2 186, CM2 246, CM2 31111 1/4 in.
Nipple, 1 in. x 2 in.
Applies only to boiler serial nos. beginning with 7201753
0408CM2 186, CM2 246, CM2 31111 in. x 2 in.
Sediment faucet0409CM2 186, CM2 246, CM2 3111
Air vent with shut-off base0410CM2 186, CM2 246, CM2 3111
Hex bushing, 1 1/4 in. x 3/8 in.0411CM2 186, CM2 246, CM2 31113/8 in.
Pressure gauge0412CM2 186, CM2 246, CM2 3111
Hex bushing0413CM2 186, CM2 246, CM2 3111
Low water cut-off0414CM2 186, CM2 246, CM2 3111
Nipple0415CM2 186, CM2 246, CM2 3111
Gas ball valve0416CM2 186, CM2 246, CM2 3111
Thermometer (Winters) 5 in. 0-250 F
Install anywhere in supply piping near boiler
0417CM2 186, CM2 246, CM2 31110-250 F
Gas pressure switch kit
Install on gas line, close to valve
0432CM2 186, CM2 246, CM2 3111
Pressure relief valve, 75 psi0401CM2 186, 246, 311175 psi
Nipple0402CM2 186, 246, 3111
90 degree street elbow0403CM2 186, 246, 3111
Hex bushing0404CM2 186, 246, 3111
Cross0405CM2 186, 246, 3111
Tee0406CM2 186, 246, 3111
Cross0407CM2 186, 246, 3111
Nipple 1 in x 2 in
Applies only to boiler serial numbers beginning with 7201753
0408CM2 186, 246, 31111 in x 2 in
Sediment faucet0409CM2 186, 246, 3111
Air vent with shut-off base0410CM2 186, 246, 3111
Hex bushing0411CM2 186, 246, 3111
Pressure gauge0412CM2 186, 246, 3111
Hex bushing0413CM2 186, 246, 3111
Low water cut-off0414CM2 186, 246, 3111
Nipple0415CM2 186, 246, 3111
Gas ball valve0416CM2 186, 246, 3111
Thermometer (Winters) 5 in, 0-250 F
Install anywhere in supply piping near boiler
0417CM2 186, 246, 31110-250 F
Parts list, installation fittings0425CM2 186, 246, 3111
Gas pressure switch kit
Install on gas line, close to valve
0432CM2 186, 246, 3111
Combustion chamber door (with refractory)0001Burner 7542292 (CM2 186)1
Combustion chamber door refractory0002Burner 7542292 (CM2 186)1
Accessory pack, small parts for burner0003Burner 7542292 (CM2 186)1
Accessory pack (mounting parts)0004Burner 7542292 (CM2 186)1
Cylinder burner0005Burner 7542292 (CM2 186)1
Burner gasket0006Burner 7542292 (CM2 186)1
Ignition electrode block0007Burner 7542292 (CM2 186)1
Ignition transformer0008Burner 7542292 (CM2 186)1
Ignition cable0009Burner 7542292 (CM2 186)1
Ionization electrode block with gasket0010Burner 7542292 (CM2 186)1
Gasket for ignition electrode0011Burner 7542292 (CM2 186)1
Wiring harness for ionization/ground0012Burner 7542292 (CM2 186)1
Burner control VUC310-B10.0030013Burner 7542292 (CM2 186)1
Programming unit HI201-B02.001 with LED display0014Burner 7542292 (CM2 186)1
Ignition transformer harness 540015Burner 7542292 (CM2 186)1
Wiring harness for fan0016Burner 7542292 (CM2 186)1
Wiring harness for gas valve0017Burner 7542292 (CM2 186)1
Pressure switch for fan inlet with 131 harness0018Burner 7542292 (CM2 186)1
2/2-way solenoid valve0019Burner 7542292 (CM2 186)1
Fan G1G170, 120/1/600021Burner 7542292 (CM2 186)1120/1/60
AC-EMI suppression filter device0022Burner 7542292 (CM2 186)1
Linkage M5
Only for models 246 and 311
0024CM2 246, 311 (listed on CM2 186 page)1
Venturi mixing pipe0025Burner 7542292 (CM2 186)1
Orifice LPG (sold as a conversion kit)
Sold as part of LPG conversion kit
0026Burner 7542292 (CM2 186)1
Gas valve VR47300027Burner 7542292 (CM2 186)1
Orifice D=0.5 in0029Burner 7542292 (CM2 186)1D=0.5 in
Fan gaskets0030Burner 7542292 (CM2 186)1
Pressure switch with 131A harness0031Burner 7542292 (CM2 186)1
Coding card0032Burner 7542292 (CM2 186)1
Wiring harness 380034Burner 7542292 (CM2 186)1
Plug console with relay contactor0035Burner 7542292 (CM2 186)1
Gas manifold with shut-off0036Burner 7542292 (CM2 186)1
Flange for gas valve0037Burner 7542292 (CM2 186)1
Sticker, gas conversion/gas type0039Burner 7542292 (CM2 186)1
O-ring for gas valve 52 x 3.5 mm0040Burner 7542292 (CM2 186)152 x 3.5 mm
Conversion kit for NG
Burner ships configured for NG with an LPG conversion kit; order NG kit to convert LPG back to NG
0050Burner 7542292 (CM2 186)1
Combustion chamber door (with refractory)0001CM2 246, 311 (burners 7542293, 7542294)1
Combustion chamber door refractory0002CM2 246, 311 (burners 7542293, 7542294)1
Accessory pack, small parts for burner0003CM2 246, 311 (burners 7542293, 7542294)1
Accessory pack, small parts for mounting0004CM2 246, 311 (burners 7542293, 7542294)1
Cylinder burner0005CM2 246, 311 (burners 7542293, 7542294)1
Burner gasket0006CM2 246, 311 (burners 7542293, 7542294)1
Ignition electrode block0007CM2 246, 311 (burners 7542293, 7542294)1
Ignition transformer0008CM2 246, 311 (burners 7542293, 7542294)1
Ignition cable0009CM2 246, 311 (burners 7542293, 7542294)1
Ionization electrode block with gasket0010CM2 246, 311 (burners 7542293, 7542294)1
Gasket for ignition electrode0011CM2 246, 311 (burners 7542293, 7542294)1
Wiring harness for ionization/ground0012CM2 246, 311 (burners 7542293, 7542294)1
Burner control VUC310-B10.0030013CM2 246, 311 (burners 7542293, 7542294)1
Programming unit HI201-B02.001 with LED display0014CM2 246, 311 (burners 7542293, 7542294)1
Ignition transformer harness 540015CM2 246, 311 (burners 7542293, 7542294)1
Wiring harness for fan0016CM2 246, 311 (burners 7542293, 7542294)1
Wiring harness for gas valve0017CM2 246, 311 (burners 7542293, 7542294)1
Pressure switch for fan inlet with 131 harness0018CM2 246, 311 (burners 7542293, 7542294)1
Servomotor STA 120V0020CM2 246, 311 (burners 7542293, 7542294)1120V
Fan G1G170, 120/1/600021CM2 246, 311 (burners 7542293, 7542294)1120/1/60
AC-EMI suppression filter device0022CM2 246, 311 (burners 7542293, 7542294)1
Inlet damper0023CM2 246, 311 (burners 7542293, 7542294)1
Linkage M50024CM2 246, 311 (burners 7542293, 7542294)1
Venturi mixing pipe0025CM2 246, 311 (burners 7542293, 7542294)1
Orifice LPG (sold as a conversion kit)
Sold as part of LPG conversion kit
0026CM2 246, 311 (burners 7542293, 7542294)1
Gas valve VR47300027CM2 246, 311 (burners 7542293, 7542294)1
Fan gaskets0030CM2 246, 311 (burners 7542293, 7542294)1
Pressure switch with 131A harness0031CM2 246, 311 (burners 7542293, 7542294)1
Coding card0032CM2 246, 311 (burners 7542293, 7542294)1
Wiring harness for step-motor0033CM2 246, 311 (burners 7542293, 7542294)1
Plug console with relay contactor0035CM2 246, 311 (burners 7542293, 7542294)1
Gas manifold with shut-off0036CM2 246, 311 (burners 7542293, 7542294)1
Flange for gas valve0037CM2 246, 311 (burners 7542293, 7542294)1
Silicone tubing0038CM2 246, 311 (burners 7542293, 7542294)1
Sticker, gas conversion/gas type0039CM2 246, 311 (burners 7542293, 7542294)1
O-ring for gas valve 52 x 3.5 mm0040CM2 246, 311 (burners 7542293, 7542294)152 x 3.5 mm
Dampening orifice0029CM2 246, 311 (burners 7542293, 7542294)1
Conversion kit for NG
Burner ships configured for NG with an LPG conversion kit; order NG kit to convert LPG back to NG
0050CM2 246, 311 (burners 7542293, 7542294)1
Outside panels0001CM2 186, 246, 3111
Accessory bag with sensors0002CM2 186, 246, 3111
Accessory bag with burner cables0003CM2 186, 246, 3111
Boiler control coding card0004CM2 186, 246, 3111

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58 (pages 10, 54, 55, 56, 57, 58, 59). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.