Viessmann · Boiler · Vitocrossal 200 CM2 series
7542294) parts
38 replacement parts that fit the Viessmann 7542294), with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Combustion chamber door (with refractory) | 0001 | 1 | |
| Combustion chamber door refractory | 0002 | 1 | |
| Accessory pack, small parts for burner | 0003 | 1 | |
| Accessory pack, small parts for mounting | 0004 | 1 | |
| Cylinder burner | 0005 | 1 | |
| Burner gasket | 0006 | 1 | |
| Ignition electrode block | 0007 | 1 | |
| Ignition transformer | 0008 | 1 | |
| Ignition cable | 0009 | 1 | |
| Ionization electrode block with gasket | 0010 | 1 | |
| Gasket for ignition electrode | 0011 | 1 | |
| Wiring harness for ionization/ground | 0012 | 1 | |
| Burner control VUC310-B10.003 | 0013 | 1 | |
| Programming unit HI201-B02.001 with LED display | 0014 | 1 | |
| Ignition transformer harness 54 | 0015 | 1 | |
| Wiring harness for fan | 0016 | 1 | |
| Wiring harness for gas valve | 0017 | 1 | |
| Pressure switch for fan inlet with 131 harness | 0018 | 1 | |
| Servomotor STA 120V | 0020 | 1 | 120V |
| Fan G1G170, 120/1/60 | 0021 | 1 | 120/1/60 |
| AC-EMI suppression filter device | 0022 | 1 | |
| Inlet damper | 0023 | 1 | |
| Linkage M5 | 0024 | 1 | |
| Venturi mixing pipe | 0025 | 1 | |
| Orifice LPG (sold as a conversion kit) Sold as part of LPG conversion kit | 0026 | 1 | |
| Gas valve VR4730 | 0027 | 1 | |
| Fan gaskets | 0030 | 1 | |
| Pressure switch with 131A harness | 0031 | 1 | |
| Coding card | 0032 | 1 | |
| Wiring harness for step-motor | 0033 | 1 | |
| Plug console with relay contactor | 0035 | 1 | |
| Gas manifold with shut-off | 0036 | 1 | |
| Flange for gas valve | 0037 | 1 | |
| Silicone tubing | 0038 | 1 | |
| Sticker, gas conversion/gas type | 0039 | 1 | |
| O-ring for gas valve 52 x 3.5 mm | 0040 | 1 | 52 x 3.5 mm |
| Dampening orifice | 0029 | 1 | |
| Conversion kit for NG Burner ships configured for NG with an LPG conversion kit; order NG kit to convert LPG back to NG | 0050 | 1 |
Same series
The Vitocrossal 200 CM2 parts list shows every part for all 20 models side by side. Other models: 186, 246, 311, 311 (burners 7542293, 311 (listed on CM2 186 page), Burner 7542292 (CM2 186), CM2 186, CM2 186 burner, CM2 246, CM2 246 burner, CM2 311, CM2 311 burner, Vitocrossal 200 CM2 186, Vitocrossal 200 CM2 246, Vitocrossal 200 CM2 311, Vitocrossal 200 CM2 400, Vitocrossal 200 CM2 500, Vitocrossal 200 CM2 620, Vitocrossal 200 CM2 620 TX.
Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58 (page 58). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.