Viessmann · Boiler · Vitocrossal 200 CM2 series
CM2 246 parts
89 replacement parts that fit the Viessmann CM2 246, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Flue gas collector (PPS) with gasket | 0001 | 1 | |
| Gasket for flue gas collector | 0002 | 1 | |
| Connector with gasket | 0003 | 1 | |
| Gasket for connector | 0004 | 1 | |
| Condensate siphon | 0005 | 1 | |
| Flue gas sensor well | 0006 | 1 | |
| Flue gas vent adaptor with clamps | 0007 | 1 | |
| Boiler temperature sensor well | 0008 | 1 | |
| Boiler inspection cup 3 in. | 0009 | 1 | 3 in. |
| Leveling bolts (accessory pack) | 0010 | 1 | |
| Boiler door hinge bracket | 0011 | 1 | |
| Installation set | 0400 | 1 | |
| Electrical junction box with all necessary wiring harness See p. 59 | 0500 | 1 | |
| Air intake kit | 0600 | 1 | |
| Bottom panel | 0012 | 1 | |
| Top panel, right | 0013 | 1 | |
| Top panel, left | 0014 | 1 | |
| Rear panel, top (with cover edge molding) | 0015 | 1 | |
| Cover edge molding | 0016 | 1 | |
| Rear panel, middle | 0017 | 1 | |
| Rear panel, bottom | 0018 | 1 | |
| Guide rail, top, right | 0019 | 1 | |
| Guide rail, top, left | 0020 | 1 | |
| Guide rail, bottom, left | 0021 | 1 | |
| Guide rail, bottom, right | 0022 | 1 | |
| Insulation blanket | 0023 | 1 | |
| Insulation blanket, front | 0024 | 1 | |
| Fasteners (accessory pack for insulation) | 0025 | 1 | |
| Front panel spring clip | 0026 | 1 | |
| Touch-up spray paint, silver | 0030 | 1 | |
| Touch-up paint stick, silver | 0031 | 1 | |
| Accessory pack, small parts for insulation | 0032 | 1 | |
| Pressure relief valve, 75 psi | 0401 | 1 | 75 psi |
| Nipple | 0402 | 1 | |
| 90 degree street elbow | 0403 | 1 | |
| Hex bushing | 0404 | 1 | |
| Cross, 1 1/4 in. | 0405 | 1 | 1 1/4 in. |
| Tee | 0406 | 1 | |
| Cross, 1 1/4 in. | 0407 | 1 | 1 1/4 in. |
| Nipple, 1 in. x 2 in. Applies only to boiler serial nos. beginning with 7201753 | 0408 | 1 | 1 in. x 2 in. |
| Sediment faucet | 0409 | 1 | |
| Air vent with shut-off base | 0410 | 1 | |
| Hex bushing, 1 1/4 in. x 3/8 in. | 0411 | 1 | 3/8 in. |
| Pressure gauge | 0412 | 1 | |
| Hex bushing | 0413 | 1 | |
| Low water cut-off | 0414 | 1 | |
| Nipple | 0415 | 1 | |
| Gas ball valve | 0416 | 1 | |
| Thermometer (Winters) 5 in. 0-250 F Install anywhere in supply piping near boiler | 0417 | 1 | 0-250 F |
| Gas pressure switch kit Install on gas line, close to valve | 0432 | 1 | |
| Linkage M5 Only for models 246 and 311 | 0024 | 1 | |
| Combustion chamber door (with refractory) | 0001 | 1 | |
| Combustion chamber door refractory | 0002 | 1 | |
| Accessory pack, small parts for burner | 0003 | 1 | |
| Accessory pack, small parts for mounting | 0004 | 1 | |
| Cylinder burner | 0005 | 1 | |
| Burner gasket | 0006 | 1 | |
| Ignition electrode block | 0007 | 1 | |
| Ignition transformer | 0008 | 1 | |
| Ignition cable | 0009 | 1 | |
| Ionization electrode block with gasket | 0010 | 1 | |
| Gasket for ignition electrode | 0011 | 1 | |
| Wiring harness for ionization/ground | 0012 | 1 | |
| Burner control VUC310-B10.003 | 0013 | 1 | |
| Programming unit HI201-B02.001 with LED display | 0014 | 1 | |
| Ignition transformer harness 54 | 0015 | 1 | |
| Wiring harness for fan | 0016 | 1 | |
| Wiring harness for gas valve | 0017 | 1 | |
| Pressure switch for fan inlet with 131 harness | 0018 | 1 | |
| Servomotor STA 120V | 0020 | 1 | 120V |
| Fan G1G170, 120/1/60 | 0021 | 1 | 120/1/60 |
| AC-EMI suppression filter device | 0022 | 1 | |
| Inlet damper | 0023 | 1 | |
| Linkage M5 | 0024 | 1 | |
| Venturi mixing pipe | 0025 | 1 | |
| Orifice LPG (sold as a conversion kit) Sold as part of LPG conversion kit | 0026 | 1 | |
| Gas valve VR4730 | 0027 | 1 | |
| Fan gaskets | 0030 | 1 | |
| Pressure switch with 131A harness | 0031 | 1 | |
| Coding card | 0032 | 1 | |
| Wiring harness for step-motor | 0033 | 1 | |
| Plug console with relay contactor | 0035 | 1 | |
| Gas manifold with shut-off | 0036 | 1 | |
| Flange for gas valve | 0037 | 1 | |
| Silicone tubing | 0038 | 1 | |
| Sticker, gas conversion/gas type | 0039 | 1 | |
| O-ring for gas valve 52 x 3.5 mm | 0040 | 1 | 52 x 3.5 mm |
| Dampening orifice | 0029 | 1 | |
| Conversion kit for NG Burner ships configured for NG with an LPG conversion kit; order NG kit to convert LPG back to NG | 0050 | 1 |
Same series
The Vitocrossal 200 CM2 parts list shows every part for all 20 models side by side. Other models: 186, 246, 311, 311 (burners 7542293, 311 (listed on CM2 186 page), 7542294), Burner 7542292 (CM2 186), CM2 186, CM2 186 burner, CM2 246 burner, CM2 311, CM2 311 burner, Vitocrossal 200 CM2 186, Vitocrossal 200 CM2 246, Vitocrossal 200 CM2 311, Vitocrossal 200 CM2 400, Vitocrossal 200 CM2 500, Vitocrossal 200 CM2 620, Vitocrossal 200 CM2 620 TX.
Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58 (pages 54, 55, 56, 57, 58). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.