OEM part number

0026 Support Bracket

Viessmann part 0026 (Front panel spring clip, Orifice LPG (sold as a conversion kit), Condensate shield, LON connecting cable, 23 ft / 7 m, LON connecting cable (7 m), RJ45). Listed for 19 models below.

Viessmann Vitocal 100-AW

Support Bracket. Fits 1 of 7 models:

Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 104, page 104. Full Vitocal 100-AW parts list

Viessmann Vitocrossal 200 CM2

Front panel spring clip. Fits 3 of 20 models:

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 55. Full Vitocrossal 200 CM2 parts list

Viessmann Vitocrossal 200 CM2

Orifice LPG (sold as a conversion kit). Fits 1 of 20 models:

Sold as part of LPG conversion kit

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 57. Full Vitocrossal 200 CM2 parts list

Viessmann Vitocrossal 200 CM2

Orifice LPG (sold as a conversion kit). Fits 3 of 20 models:

Sold as part of LPG conversion kit

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 58. Full Vitocrossal 200 CM2 parts list

Viessmann Vitodens 200-W

Condensate shield. Fits 6 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Condensate shield. Fits 3 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list

Viessmann Vitotronic 200-H

LON connecting cable, 23 ft / 7 m · 23 ft / 7 m. Fits 1 of 13 models:

Position number

Source: Vitotronic 200-H installation and service manual, p. 69, page 79. Full Vitotronic 200-H parts list

Viessmann Vitotronic 300

LON connecting cable (7 m), RJ45 · 7 m, RJ45. Fits 1 of 23 models:

Source: Vitotronic 300, GW6B installation and service instructions, p. 123, page 124. Full Vitotronic 300 parts list

Viessmann Vitotronic 300-K

LON connecting cable (7 m), RJ45 · 7 m. Fits 1 of 4 models:

Source: Vitotronic 200 and 300-K Installation and Service Instructions, p. 94, page 95. Full Vitotronic 300-K parts list

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.