Viessmann · Heat pump · Vitocal 100-AW series
AM2V 051078 parts
62 replacement parts that fit the Viessmann AM2V 051078, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Fan Grill | 0001 | 1 | |
| Front Panel | 0002 | 1 | |
| Wind Deflector | 0003 | 1 | |
| Fan Blade | 0004 | 1 | |
| Fan Motor | 0005 | 1 | |
| Left Panel | 0006 | 1 | |
| Corner Panel | 0007 | 1 | |
| Air to Refrigerant Coil | 0008 | 1 | |
| Fan Motor Bracket | 0009 | 1 | |
| Electrical Box | 0010 | 1 | |
| Top Panel | 0011 | 1 | |
| Top Rail | 0012 | 1 | |
| Electrical Box Cover | 0013 | 1 | |
| Rear Grill Panel | 0014 | 1 | |
| Interior Separation Panel | 0015 | 1 | |
| Refrigerant to System Water Plate Heat Exchanger | 0016 | 1 | |
| System Water Supply Pipe | 0017 | 1 | |
| System Water Return Pipe | 0018 | 1 | |
| Refrigerant to System Water Plate Heat Exchanger Bracket | 0019 | 1 | |
| Reversing Valve | 0020 | 1 | |
| Transformer | 0021 | 1 | |
| System Water Flow Switch | 0022 | 1 | |
| Electrical Grommet | 0023 | 1 | |
| Side Access Panel | 0024 | 1 | |
| Rear Connections Panel | 0025 | 1 | |
| Support Bracket | 0026 | 1 | |
| Isolation Fill Valve | 0027 | 1 | |
| High Pressure Switch | 0028 | 1 | |
| Low Pressure Switch | 0029 | 1 | |
| One Way Safety Valve | 0030 | 1 | |
| Electronic Expansion Valve | 0031 | 1 | |
| Filter | 0032 | 1 | |
| Electronic Expansion Valve | 0033 | 1 | |
| Schrader Valve 1 | 0034 | 1 | |
| Schrader Valve 2 | 0035 | 1 | |
| EVI Plate Heat Exchanger | 0036 | 1 | |
| EVI Plate Heat Exchanger Bracket | 0037 | 1 | |
| Bracket | 0038 | 1 | |
| Compressor | 0039 | 1 | |
| Compressor Cover 1 | 0040 | 1 | |
| Base Plate | 0041 | 1 | |
| Compressor Cover 2 | 0042 | 1 | |
| Compressor Cover 3 | 0043 | 1 | |
| Compressor Cover 4 | 0044 | 1 | |
| Transformer | 0045 | 1 | |
| Transformer Cover | 0046 | 1 | |
| Transformer Base | 0047 | 1 | |
| Mounting Bracket | 0048 | 1 | |
| Suspension Chassis | 0049 | 1 | |
| Pressure Switch | 0050 | 1 | |
| Tee Fitting (9.7X9.7) | 0051 | 1 | 9.7X9.7 |
| Tee Fitting (12.7X12.7) | 0052 | 1 | 12.7X12.7 |
| Filter | 0053 | 1 | |
| Reducer 1-a to 1 in. Brass | 0001 | 1 | |
| 1 in. Close Nipple Brass | 0002 | 1 | |
| Isolation Valve | 0003 | 1 | |
| 1-a X 1 X 1 in. Reducing Tee Brass | 0004 | 1 | |
| Pressure Relief Valve 30 PSI | 0005 | 1 | 30 PSI |
| c in. Close Nipple Brass | 0006 | 1 | |
| 1 in. X 6 in. Long Nipple Brass | 0007 | 1 | |
| 1 to c in. Reducing Elbow Brass | 0008 | 1 | |
| Changeover Relay Not shown in diagram | 0009 | 1 |
Same series
The Vitocal 100-AW parts list shows every part for all 7 models side by side. Other models: 020028, 0340043, 034043, 051078, AM2V 020028, AM2V 034043.
Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 104 (pages 104, 106). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.