OEM part number
0023 Electrical Grommet
Viessmann part 0023 (Inst/Oper/Svc Instr Vitocell CVWC, Touch-UP Spray Paint “Vitowhite”, Insulation blanket, Inlet damper, Vent pipe adaptor gasket, Harness set for power pump control module, Gasket for flue gas collector, Gasket for flue gas elbow, Harness set, PPC module, Harness set for power/pump control module). Listed for 32 models below.
Viessmann Vitocal 100-AW
Electrical Grommet. Fits 1 of 7 models:
Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 104, page 104. Full Vitocal 100-AW parts list
Viessmann Vitocell 100-V CVWC
Inst/Oper/Svc Instr Vitocell CVWC. Fits 1 of 3 models:
Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, page 31. Full Vitocell 100-V CVWC parts list
Viessmann Vitocell 100-V CVWC
Touch-UP Spray Paint “Vitowhite”. Fits 2 of 3 models:
Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, page 32. Full Vitocell 100-V CVWC parts list
Viessmann Vitocrossal 200 CM2
Insulation blanket. Fits 3 of 20 models:
Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 55. Full Vitocrossal 200 CM2 parts list
Viessmann Vitocrossal 200 CM2
Inlet damper. Fits 3 of 20 models:
Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 58. Full Vitocrossal 200 CM2 parts list
Viessmann Vitodens 200-W
Vent pipe adaptor gasket. Fits 4 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 95. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Harness set for power pump control module. Fits 4 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 98. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Gasket for flue gas collector. Fits 6 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 95. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Gasket for flue gas elbow. Fits 3 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W
Harness set, PPC module. Fits 4 of 30 models:
Source: Vitodens 200-W B2HB service instructions, page 101. Full Vitodens 200-W parts list
Viessmann Vitodens 200-W B2HA
Harness set for power pump control module. Fits 3 of 13 models:
Source: Vitodens 200-W B2HA 45, 60 Service Instructions, page 98. Full Vitodens 200-W B2HA parts list
Viessmann Vitodens 200-W B2HA
Harness set for power/pump control module. Fits 2 of 13 models:
Source: Vitodens 200-W B2HA 45, 60 Service Instructions, page 92. Full Vitodens 200-W B2HA parts list
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.