Viessmann · Boiler parts

Viessmann Vitodens 200-W B2HA: parts list

79 replacement parts with OEM part numbers for 13 models. Pick your model for a list of only the parts that fit it.

Jump to: Other

Other

PartPart #FitsQtySize / rating
Heat exchanger coil cleaning tool
Used to clear debris from heat exchanger coil gaps
7858492Vitodens 200-W B2HA 112, 150, 399, 5301
Replacement blade for heat exchanger cleaning tool
Replacement blade for the cleaning tool
7840346Vitodens 200-W B2HA 112, 150, 399, 5301
Condensate flex hose, exit0001B2HA 80/285, 88/311, 100/3521
Gasket for air intake0002B2HA 80/285, 88/311, 100/3521d=150 mm
Gasket for flue gas0003B2HA 80/285, 88/311, 100/3521d=100 mm
Test port cap0004B2HA 80/285, 88/311, 100/352set of 2
Flue gas sensor #150005B2HA 80/285, 88/311, 100/3521
Heat exchanger assembly, ASME0006B2HA 80/285, 88/311, 100/3521
Condensate drain kit0007B2HA 80/285, 88/311, 100/3521
Gas distribution pipe 20008B2HA 80/285, 88/311, 100/3521
Grommet for flue gas0009B2HA 80/285, 88/311, 100/3521DN110
Vent pipe adaptor0010B2HA 80/285, 88/311, 100/3521110/150
Combustion chamber refractory0011B2HA 80/285, 88/311, 100/3521
P-trap0012B2HA 80/285, 88/311, 100/3521
Gasket0013B2HA 80/285, 88/311, 100/352set of 521x30x2 mm
Gas distribution pipe 10014B2HA 80/285, 88/311, 100/3521
Sealing grommet0016B2HA 80/285, 88/311, 100/352each
Grommet for p-trap0017B2HA 80/285, 88/311, 100/3521
Pipe clamp0018B2HA 80/285, 88/311, 100/352set of 5DN25
Extension pipe for gas0019B2HA 80/285, 88/311, 100/35211 in. NPT
O-ring0020B2HA 80/285, 88/311, 100/352set of 524x2.5 mm
Connector for heating supply0021B2HA 80/285, 88/311, 100/3521D21
Gaskets NG/LP0022B2HA 80/285, 88/311, 100/352set of 5NG/LP
Orifice0015B2HA 80/285, 88/311, 100/3521
Harness set for power pump control module0023B2HA 80/285, 88/311, 100/3521
Nipple 3/4 in. x 1b in.
Illustrated installation fitting
0301B2HA 80 to 100, 285 to 35213/4 in. x 1b in. (1b printed unclear)
Sediment faucet 3/4 in.
Illustrated installation fitting
0302B2HA 80 to 100, 285 to 35213/4 in.
Tee 3/4 in.
Illustrated installation fitting
0303B2HA 80 to 100, 285 to 35213/4 in.
Nipple 3/4 in. x 3b in.
Illustrated installation fitting
0304B2HA 80 to 100, 285 to 35213/4 in. x 3b in. (3b printed unclear)
Reducing tee 1b in. x 1b in. x 3/4 in.
Illustrated installation fitting
0305B2HA 80 to 100, 285 to 35211b in. x 1b in. x 3/4 in. (1b printed unclear)
Gas ball valve 1 in.
Illustrated installation fitting
0306B2HA 80 to 100, 285 to 35211 in.
Pressure relief valve, 30 psig
Illustrated installation fitting
0312B2HA 80 to 100, 285 to 352130 psig
Accessory pack (metal stud mount kit)
Not illustrated
0309B2HA 80 to 100, 285 to 3521
Outdoor temperature sensor
Not illustrated
0311B2HA 80 to 100, 285 to 3521
Technical literature set
Not illustrated
0320B2HA 80 to 100, 285 to 3521
Parts list, installation fittings
Not illustrated
0325B2HA 80 to 100, 285 to 3521
Temperature gauge 2 in., 30-250 F
Install anywhere in supply piping near the boiler
0350B2HA 80 to 100, 285 to 35212 in., 30-250 F
Temperature sensor (immersion) for DHW production, NTC
Immersion sensor for domestic hot water production
0351B2HA 80 to 100, 285 to 3521NTC
Temperature sensor (immersion) for low-loss header, NTC
Only if a low-loss header is installed
0352B2HA 80 to 100, 285 to 3521NTC
Cover panel0001B2HA 45, B2HA 601
Nameplate0002B2HA 45, B2HA 601
Mounting clip (Set of 2)0003B2HA 45, B2HA 60Set of 2
Cover panel for electronics0004B2HA 45, B2HA 601
Control housing0005B2HA 45, B2HA 601
Mounting rail, left0006B2HA 45, B2HA 601
Mounting rail, right0007B2HA 45, B2HA 601
Cover panel0008B2HA 45, B2HA 601
Wall-mount bracket0009B2HA 45, B2HA 601
Support bracket, right0010B2HA 45, B2HA 601
Support bracket, left0011B2HA 45, B2HA 601
Leveling bolt0012B2HA 45, B2HA 601
Electrical box0013B2HA 45, B2HA 601
Electrical box cover0014B2HA 45, B2HA 601
Sealing grommet0015B2HA 45, B2HA 601D128/13mm
Touch-up spray paint "Vitowhite"0401B2HA 45, B2HA 601
Touch-up paint stick "Vitowhite"0402B2HA 45, B2HA 601
Lubricant0403B2HA 45, B2HA 606 g6 g
Sealing grommet0016B2HA 45, B2HA 601
Grommet cup for p-trap0017B2HA 45, B2HA 601
Sealing grommet0018B2HA 45, B2HA 601D36/14mm
Extension pipe for gas0019B2HA 45, B2HA 6011" NPT
O-Ring (Set of 5)0020B2HA 45, B2HA 60Set of 524x2.5mm
NG/LP Connector0021B2HA 45, B2HA 601D21 G¾
Fuse (Pkg of 10)0022B2HA 45, B2HA 60Pkg of 102.0A/250V
Harness set for power/pump control module0023B2HA 45, B2HA 601
Nipple ¾ in. x 1b in.
Installation fitting
030145, 601¾ in. x 1b in.
Sediment faucet ¾ in.
Installation fitting
030245, 601¾ in.
Tee, ¾ in.
Installation fitting
030345, 601¾ in.
Nipple ¾ in. x 3b in.
Installation fitting
030445, 601¾ in. x 3b in.
Reducing tee 1b in. x 1b in. x ¾ in.
Installation fitting
030545, 6011b in. x 1b in. x ¾ in.
Gas ball valve 1 in.
Installation fitting
030645, 6011 in.
Pressure relief valve, 30 psig
Installation fitting
031245, 60130 psig
Accessory pack (metal stud mount kit)
Not illustrated
030945, 601
Outdoor temperature sensor
Not illustrated
031145, 601
Parts list, installation fittings
Not illustrated
032545, 601
Technical literature set
Not illustrated
032045, 601
Temperature gauge, 2 in., 30-250°F
Install anywhere in the supply piping near the boiler
035045, 6012 in., 30-250°F
Temperature sensor (immersion) for DHW production, NTC035145, 601NTC
Temperature sensor (immersion) for low-loss header, NTC
Only if a low-loss header is installed
035245, 601NTC

Source: Vitodens 200-W B2HA 45, 60 Service Instructions (pages 26, 59, 89, 90, 92, 96, 97, 98). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.