OEM part number

0005 Fan Motor

Viessmann part 0005 (Pressure Relief Valve 30 PSI, Compressor Soft Starter, Installation set, Clamping Bracket, Spiral hose D200, Condensate siphon, Cylinder burner, Relay, Other, Hinge bottom (2 pcs), Insulation block, Temperature sensor, Control housing, Ignition electrode with gasket, Cover panel for electronics, Sensor #15 for flue gas, Flue gas sensor #15, 3-way isolation valve, DHW drain valve, Cover, left KR, Cover panel, left). Listed for 72 models below.

Viessmann Vitocal 100-AW

Fan Motor. Fits 1 of 7 models:

Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 104, page 104. Full Vitocal 100-AW parts list

Viessmann Vitocal 100-AW

Pressure Relief Valve 30 PSI · 30 PSI. Fits 3 of 7 models:

Source: Vitocal 100-AW AM2V Installation, Service and Operating Instructions, p. 104, page 106. Full Vitocal 100-AW parts list

Viessmann Vitocal 100-WA

Compressor Soft Starter. Fits 5 of 5 models:

Source: Vitocal 100-WA installation, service and operating manual, p. 80, page 80. Full Vitocal 100-WA parts list

Viessmann Vitocell 100-E

Installation set. Fits 1 of 3 models:

Source: Vitocell 100-E MSCA-20-S2 installation, service and operating instructions, p. 17, page 17. Full Vitocell 100-E parts list

Viessmann Vitocell 100-V CVWC

Clamping Bracket. Fits 1 of 3 models:

Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, page 31. Full Vitocell 100-V CVWC parts list

Viessmann Vitocell 100-V CVWC

Clamping Bracket. Fits 2 of 3 models:

Source: Viessmann Vitocell 100-V CVWC installation, service and operating instructions, page 32. Full Vitocell 100-V CVWC parts list

Viessmann Vitocrossal 200 CI2

Spiral hose D200 · D200. Fits 2 of 21 models:

Source: Vitocrossal 200 CI2 service instructions, p. 130, page 130. Full Vitocrossal 200 CI2 parts list

Viessmann Vitocrossal 200 CM2

Condensate siphon. Fits 3 of 20 models:

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 54. Full Vitocrossal 200 CM2 parts list

Viessmann Vitocrossal 200 CM2

Cylinder burner. Fits 1 of 20 models:

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 57. Full Vitocrossal 200 CM2 parts list

Viessmann Vitocrossal 200 CM2

Cylinder burner. Fits 3 of 20 models:

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58, page 58. Full Vitocrossal 200 CM2 parts list

Viessmann Vitocrossal 300 CA3B Dual Fuel

Relay · K3-14ND10 120V. Fits 1 of 43 models:

Source: Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0 Service, p. 152, page 152. Full Vitocrossal 300 CA3B Dual Fuel parts list

Viessmann Vitodens 100-W B1HE/B1KE

Other. Fits 2 of 6 models:

Parts group 0005 on the exploded parts diagram

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 103. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 100-W B1HE/B1KE

Other. Fits 1 of 6 models:

Parts group 0005 on the exploded parts diagram

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 104. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 100-W B1HE/B1KE

Other. Fits 2 of 6 models:

Position number from parts diagram

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 105. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 100-W B1HE/B1KE

Other. Fits 1 of 6 models:

Position number from parts diagram

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 106. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 100-W B1HE/B1KE

Hinge bottom (2 pcs) · Qty 2. Fits 6 of 6 models:

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 107. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 100-W B1HE/B1KE

Insulation block. Fits 3 of 6 models:

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 108. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 100-W B1HE/B1KE

Temperature sensor. Fits 3 of 6 models:

Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108, page 109. Full Vitodens 100-W B1HE/B1KE parts list

Viessmann Vitodens 200-W

Control housing. Fits 4 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 94. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Ignition electrode with gasket. Fits 4 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Cover panel for electronics. Fits 6 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 94. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Sensor #15 for flue gas. Fits 3 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 96. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Cover panel for electronics. Fits 4 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 98. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W

Control housing. Fits 3 of 30 models:

Source: Vitodens 200-W B2HB service instructions, page 95. Full Vitodens 200-W parts list

Viessmann Vitodens 200-W B2HA

Flue gas sensor #15. Fits 3 of 13 models:

Source: Vitodens 200-W B2HA 45, 60 Service Instructions, page 96. Full Vitodens 200-W B2HA parts list

Viessmann Vitodens 200-W B2HA

Control housing. Fits 2 of 13 models:

Source: Vitodens 200-W B2HA 45, 60 Service Instructions, page 89. Full Vitodens 200-W B2HA parts list

Viessmann Vitotronic 200-H

Cover, left KR. Fits 1 of 13 models:

Position number

Source: Vitotronic 200-H installation and service manual, p. 69, page 78. Full Vitotronic 200-H parts list

Viessmann Vitotronic 300

Cover panel, left. Fits 1 of 23 models:

Source: Vitotronic 300, GW6B installation and service instructions, p. 123, page 123. Full Vitotronic 300 parts list

Viessmann Vitotronic 300-K

Cover panel, left. Fits 1 of 4 models:

Source: Vitotronic 200 and 300-K Installation and Service Instructions, p. 94, page 94. Full Vitotronic 300-K parts list

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.