Viessmann · Boiler · Vitocrossal 300 CA3B Dual Fuel series
CA3B Dual Fuel 2.5 to 6.0 parts
19 replacement parts that fit the Viessmann CA3B Dual Fuel 2.5 to 6.0, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Switch-disconnector | 0002 | 1 | 690/3/40 |
| Sealing grommet | 0003 | 1 | M50 |
| Relay | 0005 | 1 | K3-14ND10 120V |
| Terminal block, 3-pole | 0006 | 1 | 3-pole |
| Terminal block, PT 2.5 | 0007 | 1 | PT 2.5 |
| Terminal block, PT 16 | 0008 | 1 | PT 16 |
| Fuse holder | 0009 | 1 | |
| Fuse Sold as a set of 10 | 0010 | Set of 10 | 2.0A/250V |
| Circuit breaker | 0011 | 1 | 16A |
| Circuit breaker | 0012 | 1 | 10A |
| Time delay relay, SPDT | 0013 | 1 | 24-240V 8A |
| Power relay, 3PDT | 0015 | 1 | 120V 10A |
| Power relay, DPDT | 0016 | 1 | 120V 10A |
| Vitogate 300 BN Optional accessory | 0017 | 1 | |
| Power supply Optional accessory | 0018 | 1 | 24VDC 0.75A |
| Dual fuel selector switch | 0019 | 1 | |
| Relay module | 0020 | 1 | 120V DC 6 A |
| Fuse Sold as 10 pieces | 0021 | 10 pieces | T6.3V/250 V |
| EA1 extension 120VAC | 0001 | 1 | 120VAC |
Same series
The Vitocrossal 300 CA3B Dual Fuel parts list shows every part for all 43 models side by side. Other models: 2.5, 3.0, 4.0, 5.0, 6.0, CA3B 2.5, CA3B 3.0, CA3B 3.5, CA3B 4.0, CA3B 5.0, CA3B 6.0, CA3B Dual Fuel 2.5, CA3B Dual Fuel 2.5 Boiler, CA3B Dual Fuel 3.0, CA3B Dual Fuel 3.0 Boiler, CA3B Dual Fuel 3.5, CA3B Dual Fuel 3.5 Boiler, CA3B Dual Fuel 4.0, CA3B Dual Fuel 4.0 Boiler, CA3B Dual Fuel 5.0, CA3B Dual Fuel 5.0 Boiler, CA3B Dual Fuel 6.0, CA3B Dual Fuel 6.0 Boiler, CA3B Dual Fuel Series 2.5, CA3B Dual Fuel Series 3.0, CA3B Dual Fuel Series 3.5, CA3B Dual Fuel Series 4.0, CA3B Dual Fuel Series 5.0, CA3B Dual Fuel Series 6.0, Vitocrossal 300 CA3 2.5 to 6.0, Vitocrossal 300 CA3B Dual Fuel 2.5, Vitocrossal 300 CA3B Dual Fuel 3.0, Vitocrossal 300 CA3B Dual Fuel 3.5, Vitocrossal 300 CA3B Dual Fuel 4.0, Vitocrossal 300 CA3B Dual Fuel 5.0, Vitocrossal 300 CA3B Dual Fuel 6.0, Vitocrossal 300 CA3B Dual Fuel Series 2.5, Vitocrossal 300 CA3B Dual Fuel Series 3.0, Vitocrossal 300 CA3B Dual Fuel Series 3.5, Vitocrossal 300 CA3B Dual Fuel Series 4.0, Vitocrossal 300 CA3B Dual Fuel Series 5.0, Vitocrossal 300 CA3B Dual Fuel Series 6.0.
Source: Vitocrossal 300 CA3B Dual Fuel Series 2.5 to 6.0 Service, p. 152 (page 152). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.