Viessmann Vitotronic 300: parts list
67 replacement parts with OEM part numbers for 23 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Vitotronic 300 boiler control Required in every application example. Certified as a component part of Viessmann boilers only. | Z001 231 | KW3 | 1 | |
| Mixing valve actuator accessory kit (includes mixing valve motor and supply temperature sensor) for Viessmann mixing valve Needed for each heating circuit with a mixing valve. Replaces / alternate: 7133 392 and 7837 524 are alternates of each other. | 7133 392 (old version) or 7837 524 (new version) | KW3 | 1 per mixing valve circuit | |
| KM-BUS Expansion Module Used in application examples 4 and 5 for two mixing valve circuits. Accessory in examples 2 and 3 with no part number listed. | 7133 393 | KW3 | 1 | |
| Vitotronic 300 control Digital boiler control, KW3 | Z001 231 | All 23 models | 1 | |
| Mixing valve actuator accessory kit (with mixing valve motor and supply temperature sensor) for mixing valve 2 Accessory kit Replaces / alternate: 7133 392 / 7837 524. | 7133 392 (old version) or 7837 524 (new version) | All 23 models | 1 | |
| KM-BUS Expansion Module For connecting several KM-BUS participants | 7133 393 | All 23 models | 1 | |
| Vitotrol 200 remote control Room setpoint adjustment; WS or RS function | 7133 378 | Vitotronic 300 | 1 | 33 VAC, 10 mA |
| Vitotrol 300 remote control Setpoint, switching times and DHW recirculation control for one heating circuit | 7133 382 | Vitotronic 300 | 1 | 33 VAC, 10 mA |
| Mixing valve actuator accessory kit (old version) Actuator torque 3 Nm; time for 90 degrees 2 minutes | 7133 392 | Vitotronic 300 | 1 | 120 VAC, 4 (2) A |
| Mixing valve actuator accessory kit (new version) Mounts directly on 3/4 to 2-1/2 in. Viessmann mixing valve; heating circuit relay 1.0 A, mixing valve relay 0.2 A Replaces / alternate: 7133 392. | 7837 524 | Vitotronic 300 | 1 | 120 VAC, 4 A, 5 W |
| Supply temperature sensor, strap-on (old version) Included with mixing valve actuator kit; 19.7 ft / 6 m cable | 7133 895 | Vitotronic 300 | 1 | Max 212 ºF (100 ºC) operation |
| Supply temperature sensor (new version) Supplied with new mixing valve actuator kit Replaces / alternate: 7133 895. | 7183 288 | Vitotronic 300 | 1 | Strap-on, 7 ft / 2.1 m cable |
| Room temperature sensor Extra room sensor used with Vitotrol 200 or 300 | 7133 379 | Vitotronic 300 | 1 | Max cable 115 ft / 35 m |
| KM-BUS Expansion Module 10 ft / 3 m cable with low voltage connectors | 7133 393 | Vitotronic 300 | 1 | Up to 6 devices on KM-BUS |
| Switching Module-V External burner demand, burner disable, program switching, error input/output, DHW circulation button | 7133 387 | Vitotronic 300 | 1 | SPDT error output contact |
| Flue gas temperature sensor Mounts on vent pipe about 1.5 times the flue pipe diameter from the boiler flue collar; needs stainless steel sensor well on condensing boilers | 7133 389 | Vitotronic 300 | 1 | 0 to 600 ºC (32 to 1112 ºF) operation |
| Boiler coding card for Vitocrossal 300 type CT3 Supplied with the boiler; only the card supplied with the boiler may be used | 1040 7820 144 | Vitocrossal 300, type CT3 | 1 | |
| Boiler coding card for Vitorond 200 VD2/VD2A Supplied with the boiler; only the card supplied with the boiler may be used | 1020 7820 142 | Vitorond 200, VD2 / VD2A | 1 | |
| Boiler coding card for Vitocrossal 200 CM2 Supplied with the boiler; only the card supplied with the boiler may be used | 1041 7820 145 | Vitocrossal 200, CM2 | 1 | |
| 120 V valve adaptor Mounts on DIN rail in connection enclosure; for 120 V valve actuator | 7134 560 | Vitotronic 300 GW2 | 1 | 120 VAC, max 0.1 FLA |
| 24 V valve adaptor Mounts on DIN rail in connection enclosure; for 24 V valve actuator | 7134 559 | Vitotronic 300 GW2 | 1 | 24 VAC, max 0.15 FLA |
| 120V valve adaptor For 120 V valve actuator on DIN rail | 7134 560 | VD2, VD2A, CT3, CM2 | 1 | 120 VAC, max. 0.1 FLA, AWG 14 wire |
| 24V valve adaptor For 24 V valve actuator on DIN rail | 7134 559 | VD2, VD2A, CT3, CM2 | 1 | 24 VAC, max. 0.15 FLA, AWG 14 wire |
| Combustion Air Device Adaptor Mounts on DIN rail in connection enclosure or boiler junction box | 7134 563 | VD2/VD2A/CT3/CM2 | 1 | 120 VAC blower, max 5 FLA |
| Line voltage motherboard Relays and outputs for pumps, controls and burner; plug-in for power supply board | 7165 782 | All 23 models | 1 | |
| Low-voltage motherboard Sensor plugs, communication and external equipment connections | 7820 290 | All 23 models | 1 | |
| Power supply unit board Low-voltage supply for all electronics | 7823 991 | All 23 models | 1 | |
| Electronics board Microprocessor with software; see board replacement tip for codings | 7828 193 | All 23 models | 1 | |
| Mixing valve extension board Relays for mixing valve motor and heating circuit pump of circuits M2 and M3 | 7820 193 | All 23 models | 1 | |
| Electronics board for mixing valve extension Connected to mixing valve extension board; processes data and activates relays | 7829 790 | All 23 models | 1 | |
| Optolink/emissions test switch board Status and fault indicators, Optolink laptop interface, emissions test switch | 7820 165 | All 23 models | 1 | |
| Programming unit Set heating program, set-points, switching times, heating curve, date, time, energy saving and party mode | 7823 986 | All 23 models | 1 | |
| Front panel with heating circuit selector buttons Displays and selects heating circuit | 7818 623 | All 23 models | 1 | |
| Fuse box Contains fixed high limit, adjustable high limit, fuses, heating system switch and TEST button | 7820 172 | All 23 models | 1 | |
| LON communication module Accessory; plugs into control unit; shows communication interruption | 7172 173 | All 23 models | 1 | |
| Terminal resistor Used on first and last control unit of LON network | 7143 497 | All 23 models | 1 on first and 1 on last control unit | |
| Input Module 0 to 10 V Connects via KM BUS to control unit; power supply required; 50 mA slow fuse | 7134 561 | Vitotronic 300 GW2 | 1 | 0 to 10 VDC input; 10 to 100 °C or 30 to 120 °C preset |
| Housing, front with support arm | 0001 | GW6B | 1 | |
| Hinges for control housing (set of 2) | 0002 | GW6B | 1 | |
| Support arm | 0003 | GW6B | 1 | |
| Flip-down cover | 0004 | GW6B | 1 | |
| Cover panel, left | 0005 | GW6B | 1 | |
| Cover panel, right (with 2 fuses) Includes 2 fuses | 0006 | GW6B | 1 | |
| Circuit boards (ETS/OptoLink, SA142/143) | 0007 | GW6B | 1 | |
| Flat cable, 10-pole | 0008 | GW6B | 1 | 10-pole |
| Flat cable, 16-pole | 0009 | GW6B | 1 | 16-pole |
| Connecting cable for emissions test switch | 0010 | GW6B | 1 | |
| Emissions test switch, 1-pole | 0011 | GW6B | 1 | 1-pole |
| Programming unit, Vitotronic 200 HI930 | 0012 | GW6B | 1 | |
| Accessory pack (low voltage plugs) | 0013 | GW6B | 1 | |
| 3-pole plug, male, #20 (set of 3) | 0014 | GW6B | 1 | #20 |
| 4-pole plug, #52 (set of 3) | 0015 | GW6B | 1 | #52 |
| 3-pole plug, #156 (set of 3) | 0016 | GW6B | 1 | #156 |
| 3-pole plug, #40 (set of 3) | 0017 | GW6B | 1 | #40 |
| 3-pole plug, #50 (set of 3) | 0019 | GW6B | 1 | #50 |
| Accessory pack (plugs #143, 145, 146) | 0020 | GW6B | 1 | |
| Technical literature set | 0100 | GW6B | 1 | |
| Installation instructions | 0101 | GW6B | 1 | |
| Operating instructions | 0102 | GW6B | 1 | |
| Parts list | 0103 | GW6B | 1 | |
| Wiring diagram | 0104 | GW6B | 1 | |
| Rating plate with serial number Serial No. 7554895 | A | GW6B | 1 | |
| DHW temperature sensor (immersion), NTC | 0021 | GW6B | 1 | NTC |
| Supply/return temperature sensor (strap-on), NTC | 0022 | GW6B | 1 | NTC |
| Connecting cable, HC-extension 156/40A | 0025 | GW6B | 1 | 156/40A |
| LON connecting cable (7 m), RJ45 | 0026 | GW6B | 1 | 7 m, RJ45 |
| LON terminal end resistor (set of 2) | 0027 | GW6B | 1 |
Source: Vitotronic 300, GW6B installation and service instructions, p. 123 (pages 5, 6, 7, 8, 22, 32, 94, 95, 96, 113, 123, 124). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.