Viessmann · Boiler · Vitotronic 300 series
Vitola 200 parts
15 replacement parts that fit the Viessmann Vitola 200, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Vitotronic 300 control Digital boiler control, KW3 | Z001 231 | 1 | |
| Mixing valve actuator accessory kit (with mixing valve motor and supply temperature sensor) for mixing valve 2 Accessory kit Replaces / alternate: 7133 392 / 7837 524. | 7133 392 (old version) or 7837 524 (new version) | 1 | |
| KM-BUS Expansion Module For connecting several KM-BUS participants | 7133 393 | 1 | |
| Line voltage motherboard Relays and outputs for pumps, controls and burner; plug-in for power supply board | 7165 782 | 1 | |
| Low-voltage motherboard Sensor plugs, communication and external equipment connections | 7820 290 | 1 | |
| Power supply unit board Low-voltage supply for all electronics | 7823 991 | 1 | |
| Electronics board Microprocessor with software; see board replacement tip for codings | 7828 193 | 1 | |
| Mixing valve extension board Relays for mixing valve motor and heating circuit pump of circuits M2 and M3 | 7820 193 | 1 | |
| Electronics board for mixing valve extension Connected to mixing valve extension board; processes data and activates relays | 7829 790 | 1 | |
| Optolink/emissions test switch board Status and fault indicators, Optolink laptop interface, emissions test switch | 7820 165 | 1 | |
| Programming unit Set heating program, set-points, switching times, heating curve, date, time, energy saving and party mode | 7823 986 | 1 | |
| Front panel with heating circuit selector buttons Displays and selects heating circuit | 7818 623 | 1 | |
| Fuse box Contains fixed high limit, adjustable high limit, fuses, heating system switch and TEST button | 7820 172 | 1 | |
| LON communication module Accessory; plugs into control unit; shows communication interruption | 7172 173 | 1 | |
| Terminal resistor Used on first and last control unit of LON network | 7143 497 | 1 on first and 1 on last control unit |
Same series
The Vitotronic 300 parts list shows every part for all 23 models side by side. Other models: 7134 555, 7143 156, 7511 362, CM2, CT3, GW2, GW6B, KW3, VD2, VD2 / VD2A, VD2/VD2A, VD2/VD2A/CT3/CM2, VD2A, Vitocrossal 200, Vitocrossal 300, Vitogas 050, RS Series, Vitogas 100, GS1 (up to 240 MBH / 70 kW), Vitogas 100, GS10 (up to 380 MBH / 111 kW), Vitorond 200, Vitotronic 300, Vitotronic 300 GW2, type CT3.
Source: Vitotronic 300, GW6B installation and service instructions, p. 123 (pages 8, 94, 95, 96). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.