Viessmann · Boiler · Vitotronic 300 series

VD2 parts

17 replacement parts that fit the Viessmann VD2, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
Vitotronic 300 control
Digital boiler control, KW3
Z001 2311
Mixing valve actuator accessory kit (with mixing valve motor and supply temperature sensor) for mixing valve 2
Accessory kit Replaces / alternate: 7133 392 / 7837 524.
7133 392 (old version) or 7837 524 (new version)1
KM-BUS Expansion Module
For connecting several KM-BUS participants
7133 3931
120V valve adaptor
For 120 V valve actuator on DIN rail
7134 5601120 VAC, max. 0.1 FLA, AWG 14 wire
24V valve adaptor
For 24 V valve actuator on DIN rail
7134 559124 VAC, max. 0.15 FLA, AWG 14 wire
Line voltage motherboard
Relays and outputs for pumps, controls and burner; plug-in for power supply board
7165 7821
Low-voltage motherboard
Sensor plugs, communication and external equipment connections
7820 2901
Power supply unit board
Low-voltage supply for all electronics
7823 9911
Electronics board
Microprocessor with software; see board replacement tip for codings
7828 1931
Mixing valve extension board
Relays for mixing valve motor and heating circuit pump of circuits M2 and M3
7820 1931
Electronics board for mixing valve extension
Connected to mixing valve extension board; processes data and activates relays
7829 7901
Optolink/emissions test switch board
Status and fault indicators, Optolink laptop interface, emissions test switch
7820 1651
Programming unit
Set heating program, set-points, switching times, heating curve, date, time, energy saving and party mode
7823 9861
Front panel with heating circuit selector buttons
Displays and selects heating circuit
7818 6231
Fuse box
Contains fixed high limit, adjustable high limit, fuses, heating system switch and TEST button
7820 1721
LON communication module
Accessory; plugs into control unit; shows communication interruption
7172 1731
Terminal resistor
Used on first and last control unit of LON network
7143 4971 on first and 1 on last control unit

Source: Vitotronic 300, GW6B installation and service instructions, p. 123 (pages 8, 94, 95, 96). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.