Viessmann · Boiler · Vitotronic 300 series

GW6B parts

45 replacement parts that fit the Viessmann GW6B, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
Vitotronic 300 control
Digital boiler control, KW3
Z001 2311
Mixing valve actuator accessory kit (with mixing valve motor and supply temperature sensor) for mixing valve 2
Accessory kit Replaces / alternate: 7133 392 / 7837 524.
7133 392 (old version) or 7837 524 (new version)1
KM-BUS Expansion Module
For connecting several KM-BUS participants
7133 3931
Line voltage motherboard
Relays and outputs for pumps, controls and burner; plug-in for power supply board
7165 7821
Low-voltage motherboard
Sensor plugs, communication and external equipment connections
7820 2901
Power supply unit board
Low-voltage supply for all electronics
7823 9911
Electronics board
Microprocessor with software; see board replacement tip for codings
7828 1931
Mixing valve extension board
Relays for mixing valve motor and heating circuit pump of circuits M2 and M3
7820 1931
Electronics board for mixing valve extension
Connected to mixing valve extension board; processes data and activates relays
7829 7901
Optolink/emissions test switch board
Status and fault indicators, Optolink laptop interface, emissions test switch
7820 1651
Programming unit
Set heating program, set-points, switching times, heating curve, date, time, energy saving and party mode
7823 9861
Front panel with heating circuit selector buttons
Displays and selects heating circuit
7818 6231
Fuse box
Contains fixed high limit, adjustable high limit, fuses, heating system switch and TEST button
7820 1721
LON communication module
Accessory; plugs into control unit; shows communication interruption
7172 1731
Terminal resistor
Used on first and last control unit of LON network
7143 4971 on first and 1 on last control unit
Housing, front with support arm00011
Hinges for control housing (set of 2)00021
Support arm00031
Flip-down cover00041
Cover panel, left00051
Cover panel, right (with 2 fuses)
Includes 2 fuses
00061
Circuit boards (ETS/OptoLink, SA142/143)00071
Flat cable, 10-pole0008110-pole
Flat cable, 16-pole0009116-pole
Connecting cable for emissions test switch00101
Emissions test switch, 1-pole001111-pole
Programming unit, Vitotronic 200 HI93000121
Accessory pack (low voltage plugs)00131
3-pole plug, male, #20 (set of 3)00141#20
4-pole plug, #52 (set of 3)00151#52
3-pole plug, #156 (set of 3)00161#156
3-pole plug, #40 (set of 3)00171#40
3-pole plug, #50 (set of 3)00191#50
Accessory pack (plugs #143, 145, 146)00201
Technical literature set01001
Installation instructions01011
Operating instructions01021
Parts list01031
Wiring diagram01041
Rating plate with serial number
Serial No. 7554895
A1
DHW temperature sensor (immersion), NTC00211NTC
Supply/return temperature sensor (strap-on), NTC00221NTC
Connecting cable, HC-extension 156/40A00251156/40A
LON connecting cable (7 m), RJ45002617 m, RJ45
LON terminal end resistor (set of 2)00271

Source: Vitotronic 300, GW6B installation and service instructions, p. 123 (pages 8, 94, 95, 96, 123, 124). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.