Viessmann · Boiler parts

Viessmann Vitotronic 300-K: parts list

32 replacement parts with OEM part numbers for 4 models. Pick your model for a list of only the parts that fit it.

Jump to: Other

Other

PartPart #FitsQtySize / rating
Housing, front with support arm0001Vitotronic 200 HO1B / 300-K MW2B1
Hinges for control housing (set of 2)0002Vitotronic 200 HO1B / 300-K MW2B1
Support arm0003Vitotronic 200 HO1B / 300-K MW2B1
Flip-down cover0004Vitotronic 200 HO1B / 300-K MW2B1
Cover panel, left0005Vitotronic 200 HO1B / 300-K MW2B1
Cover, right with fuse0006Vitotronic 200 HO1B / 300-K MW2B1
Circuit boards SA142/143 for emissions test switch and for Optolink0007Vitotronic 200 HO1B / 300-K MW2B1
Flat cable, 10-pole0008Vitotronic 200 HO1B / 300-K MW2B110-pole
Flat cable, 16-pole0009Vitotronic 200 HO1B / 300-K MW2B116-pole
Connecting cable for emissions test switch0010Vitotronic 200 HO1B / 300-K MW2B1
Switch, 1-pole emissions test switch0011Vitotronic 200 HO1B / 300-K MW2B11-pole
Programming unit, Vitotronic 200 HO1B0012Vitotronic 200 HO1B1
Accessory pack (low voltage plugs)0013Vitotronic 200 HO1B / 300-K MW2B1
3-Pole plug, male, #20 (set of 3)0014Vitotronic 200 HO1B / 300-K MW2B13-pole
4-Pole plug, #52 (set of 3)0015Vitotronic 200 HO1B / 300-K MW2B14-pole
3-Pole plug, #156 (set of 3)0016Vitotronic 200 HO1B / 300-K MW2B13-pole
3-Pole plug, #40 (set of 3)0017Vitotronic 200 HO1B / 300-K MW2B13-pole
3-Pole plug, #50 (set of 3)0019Vitotronic 200 HO1B / 300-K MW2B13-pole
Accessory pack (plugs #143, 145, 146)0020Vitotronic 200 HO1B / 300-K MW2B1
Technical literature set0100Vitotronic 200 HO1B / 300-K MW2B1
Installation instructions0101Vitotronic 200 HO1B / 300-K MW2B1
Operating instructions0102Vitotronic 200 HO1B / 300-K MW2B1
Parts list0103Vitotronic 200 HO1B / 300-K MW2B1
Wiring diagram0104Vitotronic 200 HO1B / 300-K MW2B1
Rating plate with serial number (Serial No. A)
Provide this serial number when ordering parts
AVitotronic 200 HO1B / 300-K MW2B1
DHW temperature sensor (immersion), NTC0021Vitotronic 200 HO1B / 300-K MW2B1NTC
Supply/return temperature sensor (strap-on), NTC0022Vitotronic 200 HO1B / 300-K MW2B1NTC
Connecting cable, HC-extension 156/40A0025Vitotronic 200 HO1B / 300-K MW2B1
LON connecting cable (7 m), RJ450026Vitotronic 200 HO1B / 300-K MW2B17 m
LON terminal end resistor (set of 2)0027Vitotronic 200 HO1B / 300-K MW2B1
Electrical box0110Vitotronic 200 HO1B / 300-K MW2B1
Cover panel for electrical box0111Vitotronic 200 HO1B / 300-K MW2B1

Source: Vitotronic 200 and 300-K Installation and Service Instructions, p. 94 (pages 94, 95). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.