Viessmann Vitodens 200-W: parts list
206 replacement parts with OEM part numbers for 30 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Heat exchanger coil cleaning tool Viessmann tool for clearing debris from heat exchanger coil gaps | 7840112 | Vitodens 200-W B2HB 45, 57, 160, 199 | 1 | |
| Replacement blade for coil cleaning tool Replacement blade for the part 7840112 tool | 7840346 | Vitodens 200-W B2HB 45, 57, 160, 199 | 1 | |
| Cover panel, boiler | 0001 | B2HB 45, 57, 160, 199 | 1 | |
| Nameplate Viessmann | 0002 | B2HB 45, 57, 160, 199 | 1 | |
| Mounting clip | 0003 | B2HB 45, 57, 160, 199 | set of 2 | |
| Cover panel, electronics | 0004 | B2HB 45, 57, 160, 199 | 1 | |
| Control housing | 0005 | B2HB 45, 57, 160, 199 | 1 | |
| Mounting rail, left | 0006 | B2HB 45, 57, 160, 199 | 1 | |
| Mounting rail, right | 0007 | B2HB 45, 57, 160, 199 | 1 | |
| Cover panel | 0008 | B2HB 45, 57, 160, 199 | 1 | |
| Wall-mount bracket | 0009 | B2HB 45, 57, 160, 199 | 1 | |
| Support bracket, right | 0010 | B2HB 45, 57, 160, 199 | 1 | |
| Support bracket, left | 0011 | B2HB 45, 57, 160, 199 | 1 | |
| Leveling bolt | 0012 | B2HB 45, 57, 160, 199 | 1 | |
| Electrical box | 0013 | B2HB 45, 57, 160, 199 | 1 | |
| Electrical box cover | 0014 | B2HB 45, 57, 160, 199 | 1 | |
| Installation set See installation instructions for contents | 0100 | B2HB 45, 57, 160, 199 | 1 | |
| Technical literature set | 0120 | B2HB 45, 57, 160, 199 | 1 | |
| Installation Instructions, Vitodens 200-W | 0121 | B2HB 45, 57, 160, 199 | 1 | |
| Service Instructions, Vitodens 200-W | 0122 | B2HB 45, 57, 160, 199 | 1 | |
| Operating Instructions, Vitodens 200-W | 0123 | B2HB 45, 57, 160, 199 | 1 | |
| Installation Instructions, Rigid Venting System | 0124 | B2HB 45, 57, 160, 199 | 1 | |
| Installation Instructions, Flexible Venting System | 0125 | B2HB 45, 57, 160, 199 | 1 | |
| Parts List, Vitodens 200-W | 0126 | B2HB 45, 57, 160, 199 | 1 | |
| Parts List, Installation set | 0127 | B2HB 45, 57, 160, 199 | 1 | |
| Warranty sheet | 0128 | B2HB 45, 57, 160, 199 | 1 | |
| Conversion kit NG to LP Natural gas to propane conversion | 0150 | B2HB 45, 57, 160, 199 | 1 | |
| Touch-up spray paint Vitowhite | 0151 | B2HB 45, 57, 160, 199 | 1 | |
| Touch-up paint stick Vitowhite | 0152 | B2HB 45, 57, 160, 199 | 1 | |
| Lubricant | 0153 | B2HB 45, 57, 160, 199 | 6 g | |
| Grommet for p-trap | 0015 | B2HB 45, 57, 160, 199 | 1 | |
| Condensate drain kit | 0016 | B2HB 45, 57, 160, 199 | 1 | |
| Pipe clamp, DN25 | 0017 | B2HB 45, 57, 160, 199 | set of 5 | DN25 |
| Condensate flex hose (exit) | 0018 | B2HB 45, 57, 160, 199 | 1 | |
| Extension pipe, gas | 0019 | B2HB 45, 57, 160, 199 | 1 | 1 in. NPT |
| O-ring | 0020 | B2HB 45, 57, 160, 199 | set of 5 | 24 x 2.5 mm |
| Connector, gas NG/LP | 0021 | B2HB 45, 57, 160, 199 | 1 | D21 Gc in. |
| Flue gas collector, with gasket | 0022 | B2HB 45, 57, 160, 199 | 1 | |
| Vent pipe adaptor gasket | 0023 | B2HB 45, 57, 160, 199 | 1 | |
| Burner gasket, 299 x 5.6 mm | 0001 | B2HB 45, 160, B2HB 57, 199 | 1 | 299 x 5.6 mm |
| Insulating ring | 0002 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Burner tube | 0003 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Gasket for burner tube | 0004 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Ignition electrode with gasket | 0005 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Ionization electrode with gasket | 0006 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Flapper | 0007 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Radial fan | 0008 | B2HB 45, 160, B2HB 57, 199 | 1 | RG148, 120/1/60 |
| Gas valve, with gasket | 0009 | B2HB 45, 160, B2HB 57, 199 | 1 | CES10 |
| Burner mounting flange assembly | 0010 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Ignition module | 0011 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Gasket for ionization electrode | 0012 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Gasket for ignition electrode | 0013 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Ground terminal | 0014 | B2HB 45, 160, B2HB 57, 199 | Set of 10 | |
| Orifice | 0015 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Bracket | 0016 | B2HB 45, 160, B2HB 57, 199 | Set of 3 | |
| Mounting plate for ignition module | 0017 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Turbulator disc | 0018 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Venturi extension with gasket | 0019 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Sight glass | 0020 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Accessory pack of burner screws | 0021 | B2HB 45, 160, B2HB 57, 199 | Set of 6 | |
| Fuse | 0022 | B2HB 45, 160, B2HB 57, 199 | Package of 10 | 2.0A/250V |
| Harness set for power pump control module | 0023 | B2HB 45, 160, B2HB 57, 199 | 1 | |
| Cover panel, boiler | 0001 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Control housing | 0002 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Mounting rail, left | 0003 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Mounting rail, right | 0004 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Cover panel for electronics | 0005 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Support bracket, right | 0006 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Support bracket, left | 0007 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Sealing grommet, DN60 | 0008 | B2HB 19, 26, 35, 68, 94, 125 | 1 | DN60 |
| Mounting clip (set of 2) | 0009 | B2HB 19, 26, 35, 68, 94, 125 | Set of 2 | |
| Nameplate | 0010 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Electrical box | 0011 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Electrical box cover | 0012 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Wall-mount bracket, L450 | 0013 | B2HB 19, 26, 35, 68, 94, 125 | 1 | L450 |
| Installation Set See separate Installation Set parts list | 0100 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Technical Literature Set | 0120 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Installation Instructions (title truncated on page) | 0121 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Service Instructions (title truncated on page) | 0122 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Operating Instructions (title truncated on page) | 0123 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Installation Instructions, Coaxial Venting System | 0124 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Installation Instructions, Flexible Venting System | 0125 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Parts List, Vitodens 200-W | 0126 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Parts List, Installation Set | 0127 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Warranty Sheet | 0128 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Conversion kit NG to LP Natural gas to liquid propane | 0150 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Touch-up spray paint Vitowhite | 0151 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Touch-up paint stick Vitowhite | 0152 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Lubricant 6 g | 0153 | B2HB 19, 26, 35, 68, 94, 125 | 1 | 6 g |
| Gaskets NG/LP (set of 5) | 0014 | B2HB 19, 26, 35, 68, 94, 125 | Set of 5 | |
| Sealing grommet, D=54/18 | 0015 | B2HB 19, 26, 35, 68, 94, 125 | 1 | D=54/18 |
| Support bracket set for heat exchanger | 0016 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Connecting pipe, D21 G3/4 | 0017 | B2HB 19, 26, 35, 68, 94, 125 | 1 | D21 G3/4 |
| O-ring 24x2.5 mm (set of 5) | 0018 | B2HB 19, 26, 35, 68, 94, 125 | Set of 5 | 24x2.5 mm |
| Extension pipe 3/4 in. NPT (gas) | 0019 | B2HB 19, 26, 35, 68, 94, 125 | 1 | 3/4 in. NPT |
| Flue baffle | 0022 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Gasket for flue gas collector | 0023 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Flue gas set | 0024 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Sealing grommet, DN60 | 0025 | B2HB 19, 26, 35, 68, 94, 125 | 1 | DN60 |
| Burner assembly | 0020 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Condensate shield | 0026 | B2HB 19, 26, 35, 68, 94, 125 | 1 | |
| Air intake cover | 0001 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Gasket for flue gas | 0002 | B2HB 19/68, 26/94, 35/125 | 1 | DN60 |
| Flue pipe adapter set | 0003 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Test port cap (set of 2) | 0004 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Sensor #15 for flue gas | 0005 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Heat exchanger assembly, ASME v3 with flue gas collector, vent pipe adaptor and gaskets | 0006 | B2HB 19/68, 26/94, 35/125 | 1 | ASME v3 |
| Combustion chamber refractory | 0007 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Condensate hose 1 | 0008 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Condensate trap with clip | 0009 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Condensate hose 3 | 0012 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Gas connection pipe | 0013 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Gaskets NG/LP (set of 5) | 0014 | B2HB 19/68, 26/94, 35/125 | 1 | NG/LP |
| Sealing grommet | 0015 | B2HB 19/68, 26/94, 35/125 | 1 | D=54/18 |
| Support bracket set for heat exchanger | 0016 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Connecting pipe | 0017 | B2HB 19/68, 26/94, 35/125 | 1 | D21 G¾ |
| O-ring (set of 5) | 0018 | B2HB 19/68, 26/94, 35/125 | 1 | 24x2.5 mm |
| Extension pipe (gas) | 0019 | B2HB 19/68, 26/94, 35/125 | 1 | ¾ in. NPT |
| Burner assembly | 0020 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Flue baffle | 0022 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Gasket for flue gas elbow | 0023 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Flue gas set | 0024 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Sealing grommet | 0025 | B2HB 19/68, 26/94, 35/125 | 1 | DN60 |
| Condensate shield | 0026 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Burner door assembly | 0010 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Ignition module | 0011 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Flame observation port | 0021 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Bleeding hose | 0027 | B2HB 19/68, 26/94, 35/125 | 1 | |
| Nipple 3/4 in. x 2 in. | 0301 | B2HB 19 to 35, 68 to 125 | 1 | 3/4 in. x 2 in. |
| Sediment faucet 3/4 in. | 0302 | B2HB 19 to 35, 68 to 125 | 1 | 3/4 in. |
| Tee 3/4 in. | 0303 | B2HB 19 to 35, 68 to 125 | 1 | 3/4 in. |
| Nipple 3/4 in. x 4 in. | 0304 | B2HB 19 to 35, 68 to 125 | 1 | 3/4 in. x 4 in. |
| Gas ball valve 3/4 in. | 0306 | B2HB 19 to 35, 68 to 125 | 1 | 3/4 in. |
| Pressure relief valve | 0312 | B2HB 19 to 35, 68 to 125 | 1 | 30 psig |
| Accessory pack (metal stud mount kit) Not illustrated | 0309 | B2HB 19 to 35, 68 to 125 | 1 | |
| Outdoor temperature sensor Not illustrated | 0311 | B2HB 19 to 35, 68 to 125 | 1 | |
| Air bleed key Not illustrated | 0316 | B2HB 19 to 35, 68 to 125 | 1 | |
| Temperature gauge 2 in., 30-250F Install anywhere in supply piping near the boiler | 0350 | B2HB 19 to 35, 68 to 125 | 1 | 2 in., 30-250F |
| Temperature sensor (immersion) for DHW production, NTC | 0351 | B2HB 19 to 35, 68 to 125 | 1 | NTC |
| Temperature sensor (immersion) for low-loss header, NTC Only if a low-loss header is installed | 0352 | B2HB 19 to 35, 68 to 125 | 1 | NTC |
| Cover panel | 0001 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Control housing | 0002 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Mounting rail, left | 0003 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Mounting rail, right | 0004 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Cover panel for electronics | 0005 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Support bracket, left | 0006 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Support bracket, right | 0007 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Cover panel | 0008 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Mounting clip (set of 2) | 0009 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Nameplate | 0010 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Electrical box | 0011 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Electrical box cover | 0012 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Support bracket for panel | 0013 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Grommet for P-trap | 0014 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Wall-mount bracket | 0015 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Touch-up spray paint, Vitowhite | 0401 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Touch-up paint stick, Vitowhite | 0402 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Lubricant 6 g | 0403 | B2HA 112, 399, B2HA 150, 530 | 1 | 6 g |
| Condensate hose | 0016 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Gasket A32x44x2 mm (set of 5) | 0017 | B2HA 112, 399, B2HA 150, 530 | 1 | A32x44x2 mm |
| Gasket 1 in. (set of 5) | 0018 | B2HA 112, 399, B2HA 150, 530 | 1 | 1 in. |
| Gasket 1¼ in. (set of 5) | 0019 | B2HA 112, 399, B2HA 150, 530 | 1 | 1¼ in. |
| Power/pump control module | 0020 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Extension module EA1 | 0021 | B2HA 112, 399, B2HA 150, 530 | 1 | 120/1/60 |
| Fuse 2.0 A / 250 V (pkg of 10) | 0022 | B2HA 112, 399, B2HA 150, 530 | 1 | 2.0 A / 250 V |
| Harness set, PPC module | 0023 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Clip D8 mm (set of 5) | 001 | B2HA 112, 399, B2HA 150, 530 | 1 | D8 mm |
| Boiler temperature sensor (set of 2) | 002 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Pressure gauge with clip and gasket | 003 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Flow sensor | 004 | B2HA 112, 399, B2HA 150, 530 | 1 | |
| Heat exchanger coil cleaning tool Viessmann tool for removing debris from heat exchanger coil gaps | 7858492 | Vitodens 200-W B2HA 80 to 100, 285 to 352 | 1 | |
| Replacement blade for heat exchanger cleaning tool Replacement blade for part 7858492 | 7840346 | Vitodens 200-W B2HA 80 to 100, 285 to 352 | 1 | |
| Cover panel for boiler | 0001 | B2HA 80, 88, 100 | 1 | |
| Nameplate Viessmann | 0002 | B2HA 80, 88, 100 | 1 | |
| Mounting clip (set of 2) | 0003 | B2HA 80, 88, 100 | 1 | |
| Cover panel for electronics | 0004 | B2HA 80, 88, 100 | 1 | |
| Control housing | 0005 | B2HA 80, 88, 100 | 1 | |
| Mounting rail, left | 0006 | B2HA 80, 88, 100 | 1 | |
| Mounting rail, right | 0007 | B2HA 80, 88, 100 | 1 | |
| Cover panel | 0008 | B2HA 80, 88, 100 | 1 | |
| Wall-mount bracket | 0009 | B2HA 80, 88, 100 | 1 | |
| Support bracket, right | 0010 | B2HA 80, 88, 100 | 1 | |
| Support bracket, left | 0011 | B2HA 80, 88, 100 | 1 | |
| Leveling bolt | 0012 | B2HA 80, 88, 100 | 1 | |
| Electrical box | 0013 | B2HA 80, 88, 100 | 1 | |
| Electrical box cover | 0014 | B2HA 80, 88, 100 | 1 | |
| Installation set See separate Parts List for Installation Set | 0100 | B2HA 80, 88, 100 | 1 | |
| Technical literature set | 0120 | B2HA 80, 88, 100 | 1 | |
| Installation instructions, Vitodens 200-W | 0121 | B2HA 80, 88, 100 | 1 | |
| Service instructions, Vitodens 200-W | 0122 | B2HA 80, 88, 100 | 1 | |
| Operating instructions, Vitodens 200-W | 0123 | B2HA 80, 88, 100 | 1 | |
| Parts list, Vitodens 200-W | 0124 | B2HA 80, 88, 100 | 1 | |
| Parts list, installation set | 0125 | B2HA 80, 88, 100 | 1 | |
| Installation instructions, rigid and flex pipe venting system | 0130 | B2HA 80, 88, 100 | 1 | |
| Warranty sheet | 0140 | B2HA 80, 88, 100 | 1 | |
| Conversion kit NG to LP Gas conversion kit NG > LP | 0150 | B2HA 80, 88, 100 | 1 | |
| Touch-up spray paint Vitowhite | 0160 | B2HA 80, 88, 100 | 1 | |
| Touch-up paint stick Vitowhite | 0161 | B2HA 80, 88, 100 | 1 | |
| Lubricant 6 g | 0162 | B2HA 80, 88, 100 | 1 | 6 g |
| Sealing grommet (each) | 0016 | B2HA 80, 88, 100 | 1 | |
| Grommet for p-trap | 0017 | B2HA 80, 88, 100 | 1 | |
| Pipe clamp DN25 (set of 5) | 0018 | B2HA 80, 88, 100 | 1 | DN25 |
| Extension pipe 1 in. NPT for gas | 0019 | B2HA 80, 88, 100 | 1 | 1 in. NPT |
| O-ring 24x2.5 mm (set of 5) | 0020 | B2HA 80, 88, 100 | 1 | 24x2.5 mm |
| Connector D21 for heating supply | 0021 | B2HA 80, 88, 100 | 1 | |
| Gaskets NG/LP (set of 5) | 0022 | B2HA 80, 88, 100 | 1 |
Source: Vitodens 200-W B2HB service instructions (pages 25, 60, 94, 95, 96, 97, 98, 99, 101, 102). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.