Viessmann · Boiler · Vitodens 200-W series
160 parts
62 replacement parts that fit the Viessmann 160, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Heat exchanger coil cleaning tool Viessmann tool for clearing debris from heat exchanger coil gaps | 7840112 | 1 | |
| Replacement blade for coil cleaning tool Replacement blade for the part 7840112 tool | 7840346 | 1 | |
| Cover panel, boiler | 0001 | 1 | |
| Nameplate Viessmann | 0002 | 1 | |
| Mounting clip | 0003 | set of 2 | |
| Cover panel, electronics | 0004 | 1 | |
| Control housing | 0005 | 1 | |
| Mounting rail, left | 0006 | 1 | |
| Mounting rail, right | 0007 | 1 | |
| Cover panel | 0008 | 1 | |
| Wall-mount bracket | 0009 | 1 | |
| Support bracket, right | 0010 | 1 | |
| Support bracket, left | 0011 | 1 | |
| Leveling bolt | 0012 | 1 | |
| Electrical box | 0013 | 1 | |
| Electrical box cover | 0014 | 1 | |
| Installation set See installation instructions for contents | 0100 | 1 | |
| Technical literature set | 0120 | 1 | |
| Installation Instructions, Vitodens 200-W | 0121 | 1 | |
| Service Instructions, Vitodens 200-W | 0122 | 1 | |
| Operating Instructions, Vitodens 200-W | 0123 | 1 | |
| Installation Instructions, Rigid Venting System | 0124 | 1 | |
| Installation Instructions, Flexible Venting System | 0125 | 1 | |
| Parts List, Vitodens 200-W | 0126 | 1 | |
| Parts List, Installation set | 0127 | 1 | |
| Warranty sheet | 0128 | 1 | |
| Conversion kit NG to LP Natural gas to propane conversion | 0150 | 1 | |
| Touch-up spray paint Vitowhite | 0151 | 1 | |
| Touch-up paint stick Vitowhite | 0152 | 1 | |
| Lubricant | 0153 | 6 g | |
| Grommet for p-trap | 0015 | 1 | |
| Condensate drain kit | 0016 | 1 | |
| Pipe clamp, DN25 | 0017 | set of 5 | DN25 |
| Condensate flex hose (exit) | 0018 | 1 | |
| Extension pipe, gas | 0019 | 1 | 1 in. NPT |
| O-ring | 0020 | set of 5 | 24 x 2.5 mm |
| Connector, gas NG/LP | 0021 | 1 | D21 Gc in. |
| Flue gas collector, with gasket | 0022 | 1 | |
| Vent pipe adaptor gasket | 0023 | 1 | |
| Burner gasket, 299 x 5.6 mm | 0001 | 1 | 299 x 5.6 mm |
| Insulating ring | 0002 | 1 | |
| Burner tube | 0003 | 1 | |
| Gasket for burner tube | 0004 | 1 | |
| Ignition electrode with gasket | 0005 | 1 | |
| Ionization electrode with gasket | 0006 | 1 | |
| Flapper | 0007 | 1 | |
| Radial fan | 0008 | 1 | RG148, 120/1/60 |
| Gas valve, with gasket | 0009 | 1 | CES10 |
| Burner mounting flange assembly | 0010 | 1 | |
| Ignition module | 0011 | 1 | |
| Gasket for ionization electrode | 0012 | 1 | |
| Gasket for ignition electrode | 0013 | 1 | |
| Ground terminal | 0014 | Set of 10 | |
| Orifice | 0015 | 1 | |
| Bracket | 0016 | Set of 3 | |
| Mounting plate for ignition module | 0017 | 1 | |
| Turbulator disc | 0018 | 1 | |
| Venturi extension with gasket | 0019 | 1 | |
| Sight glass | 0020 | 1 | |
| Accessory pack of burner screws | 0021 | Set of 6 | |
| Fuse | 0022 | Package of 10 | 2.0A/250V |
| Harness set for power pump control module | 0023 | 1 |
Same series
The Vitodens 200-W parts list shows every part for all 30 models side by side. Other models: 100, 125, 199, 26, 26/94, 285 to 352, 35, 35/125, 399, 530, 57, 68, 68 to 125, 88, 94, B2HA 112, B2HA 150, B2HA 80, B2HB 160, B2HB 19, B2HB 19 to 35, B2HB 19/68, B2HB 199, B2HB 45, B2HB 45, 160, B2HB 57, B2HB 57, 199, Vitodens 200-W B2HA 80 to 100, Vitodens 200-W B2HB 45.
Source: Vitodens 200-W B2HB service instructions (pages 25, 94, 95, 96, 98). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.