Viessmann · Boiler · Vitodens 222-F series

Vitodens 222-F B2TB parts

60 replacement parts that fit the Viessmann Vitodens 222-F B2TB, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
Flex pipe for tank discharge00011
Gasket set for gas connection pipe0002117x24x2 mm
Nipple00031¾ in. x G¾ in.
3-way isolation valve, DHW drain valve00051
DCW connecting pipe #2 for tank00061
Connector retaining clip (set of 2)00072
Retaining clip (set of 5)00085
O-ring set for supply/return0009118x3 mm
Connecting pipe for tank DCW00101
Pipe clip00111D=18x1.5 mm
Gasket (set of 5)0012523x30x2 mm
O-ring for DHW (set of 5)0013514.3x2.4 mm
Locking clip (set of 5)00145D=15 mm
Connecting pipe for tank recirculation00151
Flow regulator00161
Isolation valve (elbow) for DHW outlet00171
Cap00181G3/4 in. SW30
Nipple00041¾ in. NPT
Connecting pipe, DHW/heating03021
Support bracket with pipe clips03031
Pipe clip (each)03041
Connector retaining clip (set of 2)
Install security clip 0318 on this clip for DHW piping
03072
Pipe insulation0308119x9x740 mm
Gas ball valve03101¾ in. brass
Sediment faucet03111¾ in. NPT
Tee03131¾ in. brass
Security clips (set of 5)
Ships affixed to rear of boiler
03185
Flex pipe (NG/LP), full-length
Preinstalled on boiler
03011
O-ring for supply/return0305118x3 mm
Gasket for gas connection pipe
Preinstalled on boiler
0306117x24x2 mm
Outdoor temperature sensor, NTC03121
Air bleed key03141
Parts list for installation set, top03261
Temperature gauge
Install in supply piping near the boiler
035012 in. 30-250ºF
Temperature sensor (immersion) for low-loss header, NTC
If used
03511
Tee03161¾ in. brass
Gasket for gas connection pipe
Preinstalled on boiler
0309117x24x2 mm
Outdoor temperature sensor, NTC03151
Air bleed key03171
Parts list for installation set, left/right03251
Connecting pipe, DHW/heating
Top connection kit
03021
Support bracket with pipe clips
Top connection kit
03031
Pipe clip (each)
Top connection kit
03041
Connector retaining clip (set of 2)
Security clip 0318 must always be installed on this clip on the DHW piping
03072
Pipe insulation
Top connection kit
0308119x9x740 mm
Gas ball valve, brass
Top connection kit
031013/4 in.
Sediment faucet
Top connection kit
031113/4 in. NPT
Tee, brass
Top connection kit
031313/4 in.
Security clips (set of 5)
Ships affixed to rear of boiler. Must be installed on connector retaining clip 0307.
03185
Flex pipe (NG/LP), full length
Preinstalled on boiler at factory
03011
O-ring, supply/return0305118x3 mm
Gasket, gas connection pipe
Preinstalled on boiler at factory
0306117x24x2 mm
Outdoor temperature sensor, NTC03121
Air bleed key03141
Temperature gauge
Install anywhere in supply piping near boiler
035012 in., 30-250°F
Temperature sensor (immersion) for low-loss header, NTC
If used
03511
Tee, brass
Left/right side connection kit
031613/4 in.
Outdoor temperature sensor, NTC03151
Air bleed key03171
Gasket, gas connection pipe
Preinstalled on boiler at factory
0309117x24x2 mm

Source: Vitodens 222-F B2TB service instructions, p. 106 (pages 58, 104, 105, 106). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.