Viessmann · Boiler parts
Viessmann Vitodens 222-F: parts list
62 replacement parts with OEM part numbers for 19 models. Pick your model for a list of only the parts that fit it.
Models
Jump to: Other
Other
| Part | Part # | Fits | Qty | Size / rating |
|---|---|---|---|---|
| Heat exchanger coil cleaning tool Used to clear debris from heat exchanger coil gaps | 7858492 | Vitodens 222-F B2TB 19, 35, 68, 125 | 1 | |
| Replacement blade for heat exchanger cleaning tool Replacement blade for part 7858492 | 7840346 | Vitodens 222-F B2TB 19, 35, 68, 125 | 1 | |
| Flex pipe for tank discharge | 0001 | All 19 models | 1 | |
| Gasket set for gas connection pipe | 0002 | All 19 models | 1 | 17x24x2 mm |
| Nipple | 0003 | All 19 models | 1 | ¾ in. x G¾ in. |
| 3-way isolation valve, DHW drain valve | 0005 | All 19 models | 1 | |
| DCW connecting pipe #2 for tank | 0006 | All 19 models | 1 | |
| Connector retaining clip (set of 2) | 0007 | All 19 models | 2 | |
| Retaining clip (set of 5) | 0008 | All 19 models | 5 | |
| O-ring set for supply/return | 0009 | All 19 models | 1 | 18x3 mm |
| Connecting pipe for tank DCW | 0010 | All 19 models | 1 | |
| Pipe clip | 0011 | All 19 models | 1 | D=18x1.5 mm |
| Gasket (set of 5) | 0012 | All 19 models | 5 | 23x30x2 mm |
| O-ring for DHW (set of 5) | 0013 | All 19 models | 5 | 14.3x2.4 mm |
| Locking clip (set of 5) | 0014 | All 19 models | 5 | D=15 mm |
| Connecting pipe for tank recirculation | 0015 | All 19 models | 1 | |
| Flow regulator | 0016 | All 19 models | 1 | |
| Isolation valve (elbow) for DHW outlet | 0017 | All 19 models | 1 | |
| Cap | 0018 | All 19 models | 1 | G3/4 in. SW30 |
| Nipple | 0004 | All 19 models | 1 | ¾ in. NPT |
| Connecting pipe, DHW/heating | 0302 | All 19 models | 1 | |
| Support bracket with pipe clips | 0303 | All 19 models | 1 | |
| Pipe clip (each) | 0304 | All 19 models | 1 | |
| Connector retaining clip (set of 2) Install security clip 0318 on this clip for DHW piping | 0307 | All 19 models | 2 | |
| Pipe insulation | 0308 | All 19 models | 1 | 19x9x740 mm |
| Gas ball valve | 0310 | All 19 models | 1 | ¾ in. brass |
| Sediment faucet | 0311 | All 19 models | 1 | ¾ in. NPT |
| Tee | 0313 | All 19 models | 1 | ¾ in. brass |
| Security clips (set of 5) Ships affixed to rear of boiler | 0318 | All 19 models | 5 | |
| Flex pipe (NG/LP), full-length Preinstalled on boiler | 0301 | All 19 models | 1 | |
| O-ring for supply/return | 0305 | All 19 models | 1 | 18x3 mm |
| Gasket for gas connection pipe Preinstalled on boiler | 0306 | All 19 models | 1 | 17x24x2 mm |
| Outdoor temperature sensor, NTC | 0312 | All 19 models | 1 | |
| Air bleed key | 0314 | All 19 models | 1 | |
| Parts list for installation set, top | 0326 | All 19 models | 1 | |
| Temperature gauge Install in supply piping near the boiler | 0350 | All 19 models | 1 | 2 in. 30-250ºF |
| Temperature sensor (immersion) for low-loss header, NTC If used | 0351 | All 19 models | 1 | |
| Tee | 0316 | All 19 models | 1 | ¾ in. brass |
| Gasket for gas connection pipe Preinstalled on boiler | 0309 | All 19 models | 1 | 17x24x2 mm |
| Outdoor temperature sensor, NTC | 0315 | All 19 models | 1 | |
| Air bleed key | 0317 | All 19 models | 1 | |
| Parts list for installation set, left/right | 0325 | All 19 models | 1 | |
| Connecting pipe, DHW/heating Top connection kit | 0302 | Vitodens 222-F B2TB | 1 | |
| Support bracket with pipe clips Top connection kit | 0303 | Vitodens 222-F B2TB | 1 | |
| Pipe clip (each) Top connection kit | 0304 | Vitodens 222-F B2TB | 1 | |
| Connector retaining clip (set of 2) Security clip 0318 must always be installed on this clip on the DHW piping | 0307 | Vitodens 222-F B2TB | 2 | |
| Pipe insulation Top connection kit | 0308 | Vitodens 222-F B2TB | 1 | 19x9x740 mm |
| Gas ball valve, brass Top connection kit | 0310 | Vitodens 222-F B2TB | 1 | 3/4 in. |
| Sediment faucet Top connection kit | 0311 | Vitodens 222-F B2TB | 1 | 3/4 in. NPT |
| Tee, brass Top connection kit | 0313 | Vitodens 222-F B2TB | 1 | 3/4 in. |
| Security clips (set of 5) Ships affixed to rear of boiler. Must be installed on connector retaining clip 0307. | 0318 | Vitodens 222-F B2TB | 5 | |
| Flex pipe (NG/LP), full length Preinstalled on boiler at factory | 0301 | Vitodens 222-F B2TB | 1 | |
| O-ring, supply/return | 0305 | Vitodens 222-F B2TB | 1 | 18x3 mm |
| Gasket, gas connection pipe Preinstalled on boiler at factory | 0306 | Vitodens 222-F B2TB | 1 | 17x24x2 mm |
| Outdoor temperature sensor, NTC | 0312 | Vitodens 222-F B2TB | 1 | |
| Air bleed key | 0314 | Vitodens 222-F B2TB | 1 | |
| Temperature gauge Install anywhere in supply piping near boiler | 0350 | Vitodens 222-F B2TB | 1 | 2 in., 30-250°F |
| Temperature sensor (immersion) for low-loss header, NTC If used | 0351 | Vitodens 222-F B2TB | 1 | |
| Tee, brass Left/right side connection kit | 0316 | Vitodens 222-F B2TB | 1 | 3/4 in. |
| Outdoor temperature sensor, NTC | 0315 | Vitodens 222-F B2TB | 1 | |
| Air bleed key | 0317 | Vitodens 222-F B2TB | 1 | |
| Gasket, gas connection pipe Preinstalled on boiler at factory | 0309 | Vitodens 222-F B2TB | 1 | 17x24x2 mm |
Source: Vitodens 222-F B2TB service instructions, p. 106 (pages 24, 58, 104, 105, 106). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.