Viessmann · Boiler · Vitodens 100-W B1HE/B1KE series
B1KE-199 parts
35 replacement parts that fit the Viessmann B1KE-199, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Casing Position number from parts diagram | 0001 | 1 | |
| Cable Set Position number from parts diagram | 0002 | 1 | |
| Hydraulic System Position number from parts diagram | 0003 | 1 | |
| Heat Cell Position number from parts diagram | 0004 | 1 | |
| Other Position number from parts diagram | 0005 | 1 | |
| Electronic Equipment Position number from parts diagram | 0006 | 1 | |
| Programming Unit Position number from parts diagram | 0007 | 1 | |
| Rating plate with serial number Provide this serial number when ordering | A | 1 | |
| Front cover | 0001 | 1 | |
| Seal cover | 0002 | 1 | |
| Seal profile | 0003 | 1 | |
| Hinge | 0004 | 1 | |
| Hinge bottom (2 pcs) | 0005 | 2 | |
| Diaphragm grommet 88.9 mm | 0006 | 1 | 88.9 mm |
| Diaphragm grommet 80 mm | 0007 | 1 | 80 mm |
| Ventilation cover | 0008 | 1 | |
| Center clip (2 pcs) | 0009 | 2 | |
| Cable inlet grommets (2 pcs) | 0010 | 2 | |
| Screw EJOT (6 pcs) | 0011 | 6 | |
| Non-replaceable component Listed as non-replaceable; not orderable | 000A | 1 | |
| Connection elbow | 0001 | 1 | |
| Gasket set connection elbow | 0002 | 1 | |
| Thermal insulation block separation plate | 0003 | 1 | |
| Boiler flue connection 80/125 | 0004 | 1 | 80/125 |
| Temperature sensor | 0005 | 1 | |
| Flue gas temperature sensor | 0006 | 1 | |
| Flue gas gasket DN80 | 0007 | 1 | DN80 |
| Grommet DN80 | 0008 | 1 | DN80 |
| Cap plug boiler connection | 0009 | 1 | |
| Gasket set pipework | 0010 | 1 | |
| Ventilation cover | 0011 | 1 | |
| Burner door screws (6 pcs) | 0012 | 6 | |
| Burner door seal | 0013 | 1 | |
| Burner | 0014 | 1 | |
| Burner door seal HCG57 | 0015 | 1 |
Same series
The Vitodens 100-W B1HE/B1KE parts list shows every part for all 6 models side by side. Other models: B1HE-120, B1HE-150, B1HE-199, B1HE-85, B1KE-120.
Source: Vitodens 100-W B1HE/B1KE installation/service manual, p. 108 (pages 106, 107, 109, 111). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.