Viessmann · Boiler · Vitocrossal 200 CM2 series

CM2 186 parts

73 replacement parts that fit the Viessmann CM2 186, with OEM part numbers, grouped by system.

Other

PartPart #QtySize / rating
Flue gas collector (PPS) with gasket00011
Gasket for flue gas collector00021
Connector with gasket00031
Gasket for connector00041
Condensate siphon00051
Flue gas sensor well00061
Flue gas vent adaptor with clamps00071
Boiler temperature sensor well00081
Boiler inspection cup 3 in.000913 in.
Leveling bolts (accessory pack)00101
Boiler door hinge bracket00111
Installation set04001
Electrical junction box with all necessary wiring harness
See p. 59
05001
Air intake kit06001
Bottom panel00121
Top panel, right00131
Top panel, left00141
Rear panel, top (with cover edge molding)00151
Cover edge molding00161
Rear panel, middle00171
Rear panel, bottom00181
Guide rail, top, right00191
Guide rail, top, left00201
Guide rail, bottom, left00211
Guide rail, bottom, right00221
Insulation blanket00231
Insulation blanket, front00241
Fasteners (accessory pack for insulation)00251
Front panel spring clip00261
Touch-up spray paint, silver00301
Touch-up paint stick, silver00311
Accessory pack, small parts for insulation00321
Pressure relief valve, 75 psi0401175 psi
Nipple04021
90 degree street elbow04031
Hex bushing04041
Cross, 1 1/4 in.040511 1/4 in.
Tee04061
Cross, 1 1/4 in.040711 1/4 in.
Nipple, 1 in. x 2 in.
Applies only to boiler serial nos. beginning with 7201753
040811 in. x 2 in.
Sediment faucet04091
Air vent with shut-off base04101
Hex bushing, 1 1/4 in. x 3/8 in.041113/8 in.
Pressure gauge04121
Hex bushing04131
Low water cut-off04141
Nipple04151
Gas ball valve04161
Thermometer (Winters) 5 in. 0-250 F
Install anywhere in supply piping near boiler
041710-250 F
Gas pressure switch kit
Install on gas line, close to valve
04321
Pressure relief valve, 75 psi0401175 psi
Nipple04021
90 degree street elbow04031
Hex bushing04041
Cross04051
Tee04061
Cross04071
Nipple 1 in x 2 in
Applies only to boiler serial numbers beginning with 7201753
040811 in x 2 in
Sediment faucet04091
Air vent with shut-off base04101
Hex bushing04111
Pressure gauge04121
Hex bushing04131
Low water cut-off04141
Nipple04151
Gas ball valve04161
Thermometer (Winters) 5 in, 0-250 F
Install anywhere in supply piping near boiler
041710-250 F
Parts list, installation fittings04251
Gas pressure switch kit
Install on gas line, close to valve
04321
Outside panels00011
Accessory bag with sensors00021
Accessory bag with burner cables00031
Boiler control coding card00041

Source: Vitocrossal 200 CM2 186 to 311 service instructions, p. 58 (pages 54, 55, 56, 59). Part names are written by HVACopedia.

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.