Viessmann · Boiler · Vitotronic 200-H series
HK3S parts
39 replacement parts that fit the Viessmann HK3S, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Hinge | 001 | 1 | |
| Support stay | 008 | 1 | |
| Programming unit ON/OFF switch | 011 | 1 | |
| Housing front with frame (with item 001) | 013 | 1 | |
| PCB cover | 014 | 1 | |
| Front flap | 015 | 1 | |
| Casing back | 016 | 1 | |
| Mounting panel | 017 | 1 | |
| Programming unit | 018 | 1 | |
| Programming unit flap | 019 | 1 | |
| Fascia cover | 020 | 1 | |
| Ribbon cable, 14-pole Only for model HK3S | 021 | 1 | |
| Fuse holder cap for control fuse | 024 | 1 | |
| Fuse holder for control fuse | 025 | 1 | |
| Switch, 2-pole (ON/OFF switch "8") | 038 | 1 | |
| Outdoor temperature sensor | 040 | 1 | |
| DHW tank temperature sensor with plug | 043 | 1 | |
| LON communication module | 047 | 1 | |
| Electronics PCB mixing valve extension Only for model HK3S | 048 | 1 | |
| Main PCB low voltage | 049 | 1 | |
| Electronics PCB | 050 | 1 | |
| Optolink | 051 | 1 | |
| Main PCB 230 V~ | 052 | 1 | |
| Power supply unit PCB | 054 | 1 | |
| Mixing valve extension PCB Only for model HK3S | 055 | 1 | |
| Viessmann 2-wire BUS communication module | 056 | 1 | |
| Immersion temperature sensor | 067 | 1 | |
| Contact temperature sensor | 068 | 1 | |
| Connecting cable | 074 | 1 | |
| Fuse (slow) Slow-blow | 092 | 1 | 6.3 A/250 V~ |
| LON connecting cable Parts not shown in the diagram | 093 | 1 | |
| Terminator Parts not shown in the diagram | 094 | 2 pieces | |
| Plugs for sensors Parts not shown in the diagram | 100 | 3 pieces | |
| Plugs for pumps Parts not shown in the diagram | 101 | 3 pieces | |
| Plugs gS Parts not shown in the diagram | 102 | 3 pieces | |
| Plugs aBH Parts not shown in the diagram | 103 | 3 pieces | |
| Mains supply plugs fÖ Parts not shown in the diagram | 104 | 3 pieces | |
| Plugs gÖ Parts not shown in the diagram | 106 | 3 pieces | |
| Plug aVD, plug aVG and plug aVH Parts not shown in the diagram | 108 | 1 |
Same series
The Vitotronic 200-H parts list shows every part for all 13 models side by side. Other models: HK1B, HK1M, HK1S, HK1S and HK3S, HK1S only, HK3S only, Not stated, Vitotrol 200, Vitotrol 300, Vitotronic 200-H, Vitotronic 200-H HK1M, wall-mounted boilers.
Source: Vitotronic 200-H installation and service manual, p. 69 (page 69). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.