OEM part number

011 Power module (wired)

Viessmann part 011 (Gasket for flue gases, Turbulator insert, x2, 2nd pass, Insulation blanket (three part), Insulation mat, Control housing, front, Safety module (wired), Control panel, bottom right, Programming unit ON/OFF switch, Control console). Listed for 15 models below.

Viessmann Vitocontrol-S VD2/CT3/CM2

Power module (wired). Fits 1 of 7 models:

Source: Vitocontrol-S, VD2/CT3/CM2 installation and service instructions, page 193. Full Vitocontrol-S VD2/CT3/CM2 parts list

Viessmann Vitodens 100-W

Gasket for flue gases. Fits 4 of 7 models:

Source: Vitodens 100-W WB1B installation and service instructions, page 94. Full Vitodens 100-W parts list

Viessmann Vitorond 100

Turbulator insert, x2, 2nd pass · Qty 2. Fits 2 of 21 models:

For VR1 22, 91 only

Source: Vitorond 100 installation and service manual, page 49. Full Vitorond 100 parts list

Viessmann Vitorond 200 VD2

Insulation blanket (three part) · 34 x 38 in. (868 x 968 mm). Fits 1 of 15 models:

Source: Vitorond 200 VD2 Series 320 to 1080 Service Instructions, page 16. Full Vitorond 200 VD2 parts list

Viessmann Vitorond 200 VD2A

Insulation mat. Fits 1 of 8 models:

Source: Vitorond 200 VD2A service instructions, p. 18, page 18. Full Vitorond 200 VD2A parts list

Viessmann Vitotronic 100

Control housing, front. Fits 1 of 11 models:

Source: Vitotronic 100 KW10B installation manual, page 33. Full Vitotronic 100 parts list

Viessmann Vitotronic 100 GC1

Safety module (wired). Fits 1 of 12 models:

Position number from parts illustration; order no. not printed

Source: Viessmann Vitotronic 100 GC1 installation and service instructions, p. 130, page 130. Full Vitotronic 100 GC1 parts list

Viessmann Vitotronic 200

Control panel, bottom right. Fits 1 of 4 models:

Source: Vitotronic 200 Model KW2 service instructions, p. 103, page 103. Full Vitotronic 200 parts list

Viessmann Vitotronic 200-H

Programming unit ON/OFF switch. Fits 2 of 13 models:

Source: Vitotronic 200-H installation and service manual, p. 69, page 69. Full Vitotronic 200-H parts list

Viessmann Vitotronic 200-H

Control console. Fits 1 of 13 models:

Source: Vitotronic 200-H installation and service manual, p. 69, page 53. Full Vitotronic 200-H parts list

Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.