Viessmann · Boiler · Vitotronic 100 series
KW10B parts
41 replacement parts that fit the Viessmann KW10B, with OEM part numbers, grouped by system.
Other
| Part | Part # | Qty | Size / rating |
|---|---|---|---|
| Vitotronic 100 boiler control Pre-wired with Viessmann quick-connect plug-in system | 7834 238 | 1 | |
| Control fuse F1, slow blow, for control operation Wear part. Slow blow fuse for control operation. | 091 | Package of 10 | T 6.3 A / 250 V |
| Fuse, US style Wear part. US style fuse. | 092 | Package of 5 | 6.25 A |
| Fuse Wear part. | 094 | Package of 5 | 0.1 A / 250 V |
| LON communication module | 110 | 1 | |
| Relay DPDT | 115 | 1 | 24 VAC |
| Interconnector 1/4 Listed under other parts, not illustrated. | 120 | 1 | |
| Adjustable high limit Length or dimension as printed; the printed text is unclear. | 031 | 1 | 1=1750 mm |
| AHL knob | 033 | 1 | |
| Override switch | 034 | 1 | |
| Space heating circuit switch | 035 | 1 | |
| On/Off switch | 036 | 1 | |
| Outdoor temperature sensor | 040 | 1 | 5K |
| Sensor #3, boiler | 042 | 1 | 10K |
| Sensor #5, DHW | 043 | 1 | 10K |
| Control cable with #41 plug Shipped with burner or boiler. | 065 | 1 | |
| Fuse cover | 093 | 1 | |
| Motherboard | 100 | 1 | |
| Circuit board, LED | 105 | 1 | |
| Cable clip | 001 | 1 | |
| Adjustable high limit dial | 004 | 1 | |
| Fixed high limit cover | 005 | 1 | |
| Flip-down cover | 007 | 1 | |
| Control housing cover, top | 010 | 1 | |
| Control housing, front | 011 | 1 | |
| Control housing, bottom | 016 | 1 | |
| Thermometer, °C/°F | 018 | 1 | |
| Switch knockout | 019 | 1 | |
| Fuse holder | 023 | 1 | |
| Fuse holder cover | 024 | 1 | |
| Fixed high limit Dimension as printed. | 030 | 1 | 190 x 1760 mm |
| Adjustable high limit Adjustable high limit on control unit | RAK 51.1/3382 (Etheco) or TR 97.55180.251 (EGO) | 1 | 167 °F to 239 °F (75 °C to 115 °C) max. |
| Fixed high limit Fixed high limit on control unit | RAK 75.4/3412 (Etheco) or STW 56.10525.400 (EGO) | 1 | 230 °F (110 °C) max., fixed |
| Line voltage motherboard Contains relays and outputs for pumps, control elements and burner; plug-in location for power supply and boiler control section | 7165 792 | 1 | |
| Low-voltage motherboard Sensor plugs, communication connections, external equipment; plug-in locations for electronics board, LON module, 2-wire BUS module, programming unit, coding card and Optolink board | 7820 290 | 1 | |
| Power supply unit board, 120 VAC Supplies low voltage to the whole electronics | 7823 991 | 1 | 120 VAC |
| Electronics board Contains microprocessor and software; see replacement steps (codings 8A and 92) | 7828 193 | 1 | |
| Optolink/override switch board Status and fault indicators, Optolink laptop interface, override switch | 7820 165 | 1 | |
| Programming unit Inserted in control unit; used to set heating program and set points, and to show temperatures, status and faults | 7823 990 | 1 | |
| Fuse box Contains fixed high limit, adjustable high limit, fuses, heating system switch and TUV button | 7820 175 | 1 | |
| LON communication module Accessory; inserted in control unit | 7172 173 | 1 |
Same series
The Vitotronic 100 parts list shows every part for all 11 models side by side. Other models: GC1, Multi-boiler systems, Type CM2 (with Vitotronic 200), Type CT3 (with Vitotronic 200), Type VD2/VD2A (with Vitotronic 200), Vitocrossal 200, Vitocrossal 300, Vitocrossal 300 VD2/VD2A/CT3/CM2, Vitorond 200, Vitotronic 050 or Vitotronic 333 reference.
Source: Vitotronic 100 KW10B installation manual (pages 1, 3, 33, 109, 110, 111). Part names are written by HVACopedia.
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.