OEM part number
018 Programming unit
Viessmann part 018 (Condensate hose, Front section (ASME), Burner plate, Sight glass c/w gaskets, Thermometer, °C/°F). Listed for 14 models below.
Viessmann Vitocontrol-S VD2/CT3/CM2
Programming unit. Fits 1 of 7 models:
Source: Vitocontrol-S, VD2/CT3/CM2 installation and service instructions, page 193. Full Vitocontrol-S VD2/CT3/CM2 parts list
Viessmann Vitodens 100-W
Condensate hose. Fits 4 of 7 models:
Source: Vitodens 100-W WB1B installation and service instructions, page 94. Full Vitodens 100-W parts list
Viessmann Vitorond 100
Front section (ASME). Fits 2 of 21 models:
Must be sold with a split kit
Source: Vitorond 100 installation and service manual, page 53. Full Vitorond 100 parts list
Viessmann Vitorond 200 VD2
Burner plate. Fits 1 of 15 models:
Source: Vitorond 200 VD2 Series 320 to 1080 Service Instructions, page 16. Full Vitorond 200 VD2 parts list
Viessmann Vitorond 200 VD2A
Sight glass c/w gaskets. Fits 1 of 8 models:
Source: Vitorond 200 VD2A service instructions, p. 18, page 18. Full Vitorond 200 VD2A parts list
Viessmann Vitotrol 200A
Programming unit. Fits the whole series.
Source: Vitotrol 200A Installation, Operating and Service Instructions, page 14. Full Vitotrol 200A parts list
Viessmann Vitotronic 100
Thermometer, °C/°F. Fits 1 of 11 models:
Source: Vitotronic 100 KW10B installation manual, page 33. Full Vitotronic 100 parts list
Viessmann Vitotronic 100 GC1
Programming unit. Fits 1 of 12 models:
Position number from parts illustration; order no. not printed
Source: Viessmann Vitotronic 100 GC1 installation and service instructions, p. 130, page 130. Full Vitotronic 100 GC1 parts list
Viessmann Vitotronic 200
Programming unit. Fits 1 of 4 models:
Source: Vitotronic 200 Model KW2 service instructions, p. 103, page 103. Full Vitotronic 200 parts list
Viessmann Vitotronic 200-H
Programming unit. Fits 2 of 13 models:
Source: Vitotronic 200-H installation and service manual, p. 69, page 69. Full Vitotronic 200-H parts list
Part numbers are taken from the manufacturer’s published repair parts documents and are listed so you can identify the right part. Manufacturers replace and supersede numbers over time, so confirm the number with your distributor before you order, and use factory-authorized parts on equipment under warranty. Replacing gas, electrical and refrigerant parts is work for a licensed technician. HVACopedia is not affiliated with any manufacturer; brand and model names only identify the equipment.